E 1100
Burner Setup
wc_tx001811gb.fm
85
6.3
Setting the “Z” Distance
Requirements
Burner removed from the machine
T501 gauge or measuring device
Procedure
Follow the procedure below to set the “Z” distance on “L” heads.
1. Remove the burner from the machine.
2. Loosen the spline nut
(b)
.
3. Loosen the hex head screw
(e)
.
4. Butt-up the T501 gauge or a ruler to the leading edge of the head
(d)
.
5. Slide the head in or out as needed so that the “C” mark
(c)
of the T501 gauge
aligns with the outside edge of the conical-shaped shroud. Or, adjust the
distance from the leading edge of the head to the outside edge of the conical-
shaped shroud to be 44.5 mm (1-3/4 in.).
6. Tighten the hex screw
(e)
.
7. Tighten the spline nut
(b)
.
8. Mark
(x)
the escutcheon plate for later reference.
Result
The “Z” distance has now been set.
x
Summary of Contents for 5000620172
Page 19: ...E 1100 Safety Information wc_si000628gb fm 19 Notes ...
Page 20: ...Labels E 1100 20 wc_si000629gb fm 2 Labels 2 1 Label Locations wc_gr009588 ...
Page 105: ...ghi_tx001153gb fm 105 E 1100 Maintenance ...
Page 122: ...Technical Data E 1100 122 wc_td000476gb fm 10 5 Dimensions cm in wc_gr008706 ...
Page 133: ...wc_tx001673gb fm 133 Fuji Temperature Controller ...
Page 134: ...wc_tx001673gb fm 134 Fuji Temperature Controller ...
Page 151: ...E 1100 Schematics wc_tx001908gb fm 151 11 3 Burner System Circuit ...
Page 152: ...Schematics E 1100 152 wc_tx001908gb fm 11 4 Circulation System Circuit ghi_gr005662 ...
Page 153: ...E 1100 Schematics wc_tx001908gb fm 153 11 5 Rewind System Circuit ...
Page 158: ...Schematics E 1100 158 wc_tx001908gb fm 11 10 Genset DC Wiring Diagram ...
Page 160: ......
Page 161: ......