wc_tx003152gb.fm
109
E 1100 / HSH 350
Genset Maintenance
8.4
Servicing the Air Cleaner
Requirements
Compressed air—maximum 73 psi (5 bar)
Engine stopped
Engine cooled
Frequency
The air cleaner element should be replaced as needed or every 500 hours.
Procedure
Perform the procedure below to service the air cleaner.
1. Remove the air cleaner cover
(a)
.
2. Unscrew and remove knurled nut
(b)
and take off air cleaner element
(c)
.
3. Clean the filter compartment and the cover. Dirt and other foreign debris must
not be allowed to enter the engine's air inlet points.
4. The filter element should either be replaced or, depending upon the degree of
contamination, cleaned or checked as indicated below.
Dry Contamination:
Use compressed air to blow through the filter element from the inside outwards,
until no further dirt emerges.
NOTICE:
The air pressure must not exceed 73 psi (5 bar).
Moist or Oily Contamination:
Replace the filter element.
This procedure continues on the next page.
wc_gr009557
a
b
c
Summary of Contents for 5000620172
Page 19: ...E 1100 Safety Information wc_si000628gb fm 19 Notes ...
Page 20: ...Labels E 1100 20 wc_si000629gb fm 2 Labels 2 1 Label Locations wc_gr009588 ...
Page 105: ...ghi_tx001153gb fm 105 E 1100 Maintenance ...
Page 122: ...Technical Data E 1100 122 wc_td000476gb fm 10 5 Dimensions cm in wc_gr008706 ...
Page 133: ...wc_tx001673gb fm 133 Fuji Temperature Controller ...
Page 134: ...wc_tx001673gb fm 134 Fuji Temperature Controller ...
Page 151: ...E 1100 Schematics wc_tx001908gb fm 151 11 3 Burner System Circuit ...
Page 152: ...Schematics E 1100 152 wc_tx001908gb fm 11 4 Circulation System Circuit ghi_gr005662 ...
Page 153: ...E 1100 Schematics wc_tx001908gb fm 153 11 5 Rewind System Circuit ...
Page 158: ...Schematics E 1100 158 wc_tx001908gb fm 11 10 Genset DC Wiring Diagram ...
Page 160: ......
Page 161: ......