E 1100
Accessories
wc_tx001844gb.fm
77
Continued from the previous page.
3. Disconnect the hose on the reel
(a)
from the HTF supply hose
(b)
.
4. Connect the 1-2 adapter
(c)
to the HTF supply hose
(b)
.
5. Connect the Heat Exchanger supply hoses
(d)
to the 1-2 adapter
(c)
.
6. Connect the 2-1 adapter
(f)
to the accessory HTF return port
(g).
7. Connect the Heat Exchanger HTF return hoses
(e) to
the 2-1 adapter
(f)
.
8. Insulate the supply and return hoses.
9. Connect the Heat Exchangers to the appropriate electrical source.
NOTICE:
Only turn on the pump when the Heat Exchangers are connected.
Turning on the pump when the Heat Exchangers are not connected will cause
excess system pressure which will damage the pump.
10.Start the E 1100 and operate it with the temperature controller set to 80°C.
11.Turn on the Heat Exchangers.
Result
The Heat Exchangers have now been connected and are operating.
wc gr008516
HX 50
HX 50
b
c
d
a
e
g
f
Summary of Contents for 5000620172
Page 19: ...E 1100 Safety Information wc_si000628gb fm 19 Notes ...
Page 20: ...Labels E 1100 20 wc_si000629gb fm 2 Labels 2 1 Label Locations wc_gr009588 ...
Page 105: ...ghi_tx001153gb fm 105 E 1100 Maintenance ...
Page 122: ...Technical Data E 1100 122 wc_td000476gb fm 10 5 Dimensions cm in wc_gr008706 ...
Page 133: ...wc_tx001673gb fm 133 Fuji Temperature Controller ...
Page 134: ...wc_tx001673gb fm 134 Fuji Temperature Controller ...
Page 151: ...E 1100 Schematics wc_tx001908gb fm 151 11 3 Burner System Circuit ...
Page 152: ...Schematics E 1100 152 wc_tx001908gb fm 11 4 Circulation System Circuit ghi_gr005662 ...
Page 153: ...E 1100 Schematics wc_tx001908gb fm 153 11 5 Rewind System Circuit ...
Page 158: ...Schematics E 1100 158 wc_tx001908gb fm 11 10 Genset DC Wiring Diagram ...
Page 160: ......
Page 161: ......