ghi_tx001153gb.fm
98
Maintenance
E 1100
7.9
Cleaning the HTF Strainer
Requirements
Machine shut down
Source of clean, warm water
Removal
Perform the procedure below to clean the HTF strainer.
Note:
In the interests of environmental protection, place a plastic sheet and a
container under the machine to collect any liquid which drains off. Dispose of this
liquid in accordance with local environmental protection laws.
1. Loosen, but do not remove, the top screw
(a)
.
Note:
There is a second screw
(b)
under the canister
(c)
. Hold this screw while
loosening the screw
(a)
.
2. Tap on screw
(a)
with a hammer to release the gasket seal.
3. Remove the canister
(c)
by removing screw
(a)
—support the canister while
doing so.
4. Dispose of the HTF that remains in the canister.
5. Remove the gasket
(d)
from the canister. Replace it if it is damaged.
6. Remove the strainer basket
(e)
from the canister.
7. Rinse the strainer basket and the canister with clean, warm water.
This procedure continues on the next page.
Summary of Contents for 5000620172
Page 19: ...E 1100 Safety Information wc_si000628gb fm 19 Notes ...
Page 20: ...Labels E 1100 20 wc_si000629gb fm 2 Labels 2 1 Label Locations wc_gr009588 ...
Page 105: ...ghi_tx001153gb fm 105 E 1100 Maintenance ...
Page 122: ...Technical Data E 1100 122 wc_td000476gb fm 10 5 Dimensions cm in wc_gr008706 ...
Page 133: ...wc_tx001673gb fm 133 Fuji Temperature Controller ...
Page 134: ...wc_tx001673gb fm 134 Fuji Temperature Controller ...
Page 151: ...E 1100 Schematics wc_tx001908gb fm 151 11 3 Burner System Circuit ...
Page 152: ...Schematics E 1100 152 wc_tx001908gb fm 11 4 Circulation System Circuit ghi_gr005662 ...
Page 153: ...E 1100 Schematics wc_tx001908gb fm 153 11 5 Rewind System Circuit ...
Page 158: ...Schematics E 1100 158 wc_tx001908gb fm 11 10 Genset DC Wiring Diagram ...
Page 160: ......
Page 161: ......