background image

1

Propane (LPG) Model

B9945L

Supplemental Heater

Natural Gas Model

B9945N

Supplemental Heater

UNITED STATES STOVE COMPANY

227 Industrial Park Road • P.O. Box 151 • South Pittsburg, TN 37380 • (423) 837-2100

VENT-FREE PEDESTAL GAS HEATER

 INSTALLATION AND OPERATION INSTRUCTIONS

This is an unvented gas-fired
heater.  It uses air (oxygen) from
the room in which it is installed.
Provisions for adequate combus-
tion and ventilation air must be
provided.  Refer to "Adequate
Combustion And Ventilation Air"
on page(s) 6 of this manual.

W

W

W

W

WARNING:

ARNING:

ARNING:

ARNING:

ARNING:  If the inf

  If the inf

  If the inf

  If the inf

  If the information in this man

ormation in this man

ormation in this man

ormation in this man

ormation in this manual is not

ual is not

ual is not

ual is not

ual is not

fffffollo

ollo

ollo

ollo

ollowed e

wed e

wed e

wed e

wed exactl

xactl

xactl

xactl

xactly

y

y

y

y,,,,, a fire or e

 a fire or e

 a fire or e

 a fire or e

 a fire or explosion ma

xplosion ma

xplosion ma

xplosion ma

xplosion may result

y result

y result

y result

y result

causing pr

causing pr

causing pr

causing pr

causing proper

oper

oper

oper

operty dama

ty dama

ty dama

ty dama

ty damag

g

g

g

ge

e

e

e

e,,,,, per

 per

 per

 per

 personal injur

sonal injur

sonal injur

sonal injur

sonal injury

y

y

y

y,,,,, or loss of

 or loss of

 or loss of

 or loss of

 or loss of

life.

life.

life.

life.

life.

~Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
~WHA

~WHA

~WHA

~WHA

~WHAT 

T T

T

T

T

TO DO IF 

O DO IF 

O DO IF 

O DO IF 

O DO IF Y

Y

Y

Y

YOU SMELL GAS

OU SMELL GAS

OU SMELL GAS

OU SMELL GAS

OU SMELL GAS

• Do not try to light any appliance.

• Do not try to light any appliance.

• Do not try to light any appliance.

• Do not try to light any appliance.

• Do not try to light any appliance.
• Do not touch any electrical switch; do not

• Do not touch any electrical switch; do not

• Do not touch any electrical switch; do not

• Do not touch any electrical switch; do not

• Do not touch any electrical switch; do not

use any phone in your building.

use any phone in your building.

use any phone in your building.

use any phone in your building.

use any phone in your building.

• Immediately call your gas supplier from a

• Immediately call your gas supplier from a

• Immediately call your gas supplier from a

• Immediately call your gas supplier from a

• Immediately call your gas supplier from a

neighbor's phone.  Follow the gas supplier's

neighbor's phone.  Follow the gas supplier's

neighbor's phone.  Follow the gas supplier's

neighbor's phone.  Follow the gas supplier's

neighbor's phone.  Follow the gas supplier's
instructions.

instructions.

instructions.

instructions.

instructions.

• If y

• If y

• If y

• If y

• If you cannot reac

ou cannot reac

ou cannot reac

ou cannot reac

ou cannot reach y

h y

h y

h y

h your gas supplier

our gas supplier

our gas supplier

our gas supplier

our gas supplier,,,,, call

 call

 call

 call

 call

the fire department.

the fire department.

the fire department.

the fire department.

the fire department.

~Installation and service must be performed by a

~Installation and service must be performed by a

~Installation and service must be performed by a

~Installation and service must be performed by a

~Installation and service must be performed by a
qualified installer

qualified installer

qualified installer

qualified installer

qualified installer,,,,, ser

 ser

 ser

 ser

 service a

vice a

vice a

vice a

vice ag

g

g

g

genc

enc

enc

enc

ency

y

y

y

y,,,,, or the gas supplier

 or the gas supplier

 or the gas supplier

 or the gas supplier

 or the gas supplier.....

W

W

W

W

WARNING:

ARNING:

ARNING:

ARNING:

ARNING:

Do not use a blower insert,

Do not use a blower insert,

Do not use a blower insert,

Do not use a blower insert,

Do not use a blower insert,

heat exchanger insert or other

heat exchanger insert or other

heat exchanger insert or other

heat exchanger insert or other

heat exchanger insert or other

accessories not approved

accessories not approved

accessories not approved

accessories not approved

accessories not approved

fffffor use with this heater

or use with this heater

or use with this heater

or use with this heater

or use with this heater.....

Save this manual for

future reference.

This appliance may be installed in an aftermarket* manufactured (mobile) home,

This appliance may be installed in an aftermarket* manufactured (mobile) home,

This appliance may be installed in an aftermarket* manufactured (mobile) home,

This appliance may be installed in an aftermarket* manufactured (mobile) home,

This appliance may be installed in an aftermarket* manufactured (mobile) home,

where not prohibited by state or local codes.

where not prohibited by state or local codes.

where not prohibited by state or local codes.

where not prohibited by state or local codes.

where not prohibited by state or local codes.

*Aftermarket:  Completion of sale, not for purpose of resale, from the manufacturer

This appliance is onl

This appliance is onl

This appliance is onl

This appliance is onl

This appliance is only f

y f

y f

y f

y for use with the type of gas indicated on the rating plate

or use with the type of gas indicated on the rating plate

or use with the type of gas indicated on the rating plate

or use with the type of gas indicated on the rating plate

or use with the type of gas indicated on the rating plate.....  

  

  

  

  This appli-

This appli-

This appli-

This appli-

This appli-

ance is not con

ance is not con

ance is not con

ance is not con

ance is not conver

ver

ver

ver

vertib

tib

tib

tib

tible f

le f

le f

le f

le for use with other gases.

or use with other gases.

or use with other gases.

or use with other gases.

or use with other gases.

851369-C

®

Summary of Contents for Ambiance B9945N

Page 1: ...cannot reac ou cannot reac ou cannot reac ou cannot reach y h y h y h y h your gas supplier our gas supplier our gas supplier our gas supplier our gas supplier call call call call call the fire depart...

Page 2: ...erative that control compartments burners and circulating air passageways of the appliance be kept clean IMPORTANT SAFETY INFORMATION 3 4 PRODUCT FEATURES 4 SPECIFICATIONS 5 CONTENTS 5 ITEMS REQUIRED...

Page 3: ...ghsurfacetemperatureandshouldstayawaytoavoidburns orclothingignition Youngchildrenshouldbecarefullysupervisedwhentheyareinthesameroomwiththeappliance IMPOR IMPOR IMPOR IMPOR IMPORT T T T TANT SAFETY I...

Page 4: ...ials gasolineandotherflammablevaporsandliquids Anysafetyscreenorguardremovedforservicingmustbereplacedpriortooperatingtheheater Thisvent freegasheaterisintendedtobesmokeless Iflogsappeartosmoke turnof...

Page 5: ...VENT SKIN IRRIT O PREVENT SKIN IRRIT O PREVENT SKIN IRRIT O PREVENT SKIN IRRITA A A A ATION FR TION FR TION FR TION FR TION FROM LOOSE FIBERS OM LOOSE FIBERS OM LOOSE FIBERS OM LOOSE FIBERS OM LOOSE F...

Page 6: ...which complies with local codes Sediment trap Pipe sealant approved for use with Pipe wrench propane LPG resistant to sulfur compounds CODES CODES CODES CODES CODES Adheretoalllocalcodesorintheirabse...

Page 7: ...n uction uction pr pr pr pr pro o o o ovide vide vide vide vide adequate combustion and ventilation air by one of the methods described in the adequate combustion and ventilation air by one of the met...

Page 8: ...learances between mantel shelf and the top of the heater If your installation does not meet the below minimum clearances you must Raise the mantel to an acceptable height OR Remove the mantel ALL MINI...

Page 9: ...o allow full gas when permitted by local codes Only use pipe of 1 2 or greater diameter to allow full gas when permitted by local codes Only use pipe of 1 2 or greater diameter to allow full gas when...

Page 10: ...r for leaks using soap and water solution after completing connection DO NOT USE AN OPEN FLAME The heater regulator controls the burner pressure which should be checked at the pressure test point loca...

Page 11: ...s pine cones pine cones pine cones pine cones pine cones v v v v ver er er er ermiculite or r miculite or r miculite or r miculite or r miculite or roc oc oc oc ock w k w k w k w k wool to the hea ool...

Page 12: ...ights the pilot If Piezo fails thenlightthepilotusingmatches Refertomatchlightinginstructions page14 Whenlightingthepilot follow theseinstructionsexactly BEFORE LIGHTING smell all around the appliance...

Page 13: ...knob clockwise to ON 10 Wait about one minute then turn burner switch D to ON It will take a few minutes for the thermopile located on top of the pilot to heat up NOTE If unit is equipped with remote...

Page 14: ...terisinoperationandshouldjusttouchthetopofthe thermocouple tip FIGURE 9 Ifthepilotflamedoesnottouchthethermocouple then the main burner is unlikely to function reliably FIGURE 10 WARNING WARNING WARNI...

Page 15: ...ction Annual Cleaning Inspection Inspect and clean burner air intake holes Inspect and clean all burner ports Inspect ODS pilot for operation and accumulation of lint at air intake holes Verify flame...

Page 16: ...ASSEMBLY REPLACEMENT PARTS HEATER ASSEMBLY REPLACEMENT PARTS HEATER ASSEMBLY REPLACEMENT PARTS HEATER ASSEMBLY REPLACEMENT PARTS HEATER ASSEMBLY REPLACEMENT PARTS 5 3 9 7 6 18 10 4 17 15 16 8 12 11 1...

Page 17: ...774 LOUVER FRAME 1 11 B24457 CONTROL DOOR 1 12 89899 BRASS KNOB 1 13 83323 8 32 x 3 8 MACHINE SCREW 1 14 24800 WINDOW FRAME BRACKET BOTTOM 2 15 24799 WINDOW FRAME BRACKET TOP 2 16 69236 WINDOW FRAME A...

Page 18: ...18 BURNER LOG ASSEMBLY BURNER LOG ASSEMBLY BURNER LOG ASSEMBLY BURNER LOG ASSEMBLY BURNER LOG ASSEMBLY 11 1 17 15 16 14 3 2 8 7 9 10 6 4 5 12 13...

Page 19: ...198 CONTROL VALVE NATURAL 1 81202 CONTROL VALVE LIQUID PROPANE 1 4 83464 10 32 x 3 8 PH HD MACHINE SCREW 4 5 89937 BURNER GAS LINE 31 ORIFICE NAT 1 89938 BURNER GAS LINE 49 ORIFICE L P 1 N S 83172 10A...

Page 20: ...gnitor Ventilateroom Stopusingodor causing products while heater is running Locate and correct all leaks Appliance burning vapors from paint hair spray glues etc Gas leak Appliance produces unwanted o...

Page 21: ...roblem will stop after a few hours of operation Run the heater with the damper open if you have one or open a window for the first few hours Log heater is intended to be smokeless Turn OFF heater and...

Page 22: ...9945 THIS OPTIONAL F40 BLOWER KIT IS AVAILABLE WHERE YOU PURCHASED THIS HEATER OR YOU CAN ORDER DIRECT FROM THE FACTORY BY CONTACTING THE PARTS DEPARTMENT AT THE NUMBER AND ADDRESS ON THE BACK PAGE OF...

Page 23: ...ING DIAGRAM FOR GENERATOR ASSEMBLY WIRING DIAGRAM FOR GENERATOR ASSEMBLY 50 60 70 80 90 21 10 32 c 50 60 70 80 90 21 10 32 c MODEL WSK60 WALL SWITCH KIT OPTIONAL KITS FOR THE 9945 OPTIONAL KITS FOR TH...

Page 24: ...F STANDARD WIRING FROM FACTORY STANDARD WIRING FROM FACTORY STANDARD WIRING FROM FACTORY STANDARD WIRING FROM FACTORY STANDARD WIRING FROM FACTORY WIRING OF THE RCK60 REMOTE CONTROL KIT WIRING OF THE...

Page 25: ...IT THE RCK60 REMOTE CONTROL KIT THE RCK60 REMOTE CONTROL KIT Remember the Rocker Switch must be turned to OFF while using the Wall Switch PILOT O F F PILOT O N Sit E A TP TH TP TH ROCKER SWITCH CONTRO...

Page 26: ...26 NOTES NOTES NOTES NOTES NOTES...

Page 27: ...R WAR THIS WARRANTY IS EXPRESSLY IN LIEU OF OTHER WAR THIS WARRANTY IS EXPRESSLY IN LIEU OF OTHER WAR THIS WARRANTY IS EXPRESSLY IN LIEU OF OTHER WAR THIS WARRANTY IS EXPRESSLY IN LIEU OF OTHER WAR RA...

Page 28: ...EP IN A SAFE PLACE FOR FUTURE REFERENCE WHEN WRITING ALWAYS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED INSIDE THE FRONT OF THE HEATER WHEN ORDERING REPAIR PARTS OR OPTIONS ALWAYS GI...

Reviews: