Test conditions for washing machines
The washing machine shall be tested in a complete laundry programme
incorporating the normal wash-cycle filled with the rated load of double
hemmed, pre-washed cotton cloths' size approximately
70cm x 70cm, dry weight from 140 g/m2 to 174 g/m2.
The temperature of the fill water shall be
•
65°C ±5°C for washing machines without heater elements;
•
15°C ±5°C for other washing machines
For washing machines with a programmer, the 60°C cotton programme
without pre-wash shall be used.
If the washing machine does not incorporate a programmer, the water is
heated to 90°C ±5°C or lower if steady conditions are established, before
starting the first wash period.
Neglect simultaneous switching of heater and motor in the evaluation of dc,
dmax and d(t).
Pst and Plt shall be evaluated.
Test conditions for tumbler dryers
The dryer shall be tested with 50% of the load as specified for normal
operation in IEC 335-2-11
If a control of the drying degree is available the test shall be performed at
the maximum and minimum settings.
Pst and Plt shall be evaluated.
Test conditions for refrigerators
Refrigerators shall be operated continuously with the door closed. Adjust
the thermostat to the mid-value of the adjusting range. The cabinet shall be
empty and not heated. The measurement shall be made after a steady state
has been reached.