Additionally, the flicker Pst. z caused by switching the heater on and off
has to be measured within a ten-minute interval. In this interval the power
consumption has to be changed twice in the quickest possible way between
the stages P = 0 and P = Pmax (sequence: 0 - Pmax - 0 - Pmax - 0)
The duty cycle of the heater shall be 50% that is Pmax during 5 minutes.
Evaluate the resultant Pst value by:
and compare against the limit value.
Plt shall not be evaluated.
Test conditions for arc welding equipment and allied processes
For arc-welding equipment, attended whilst in use, and allied processes,
dmax shall be evaluated against the 7% limit for manual switching using
the 24-measurement method.
Additionally, equipment designed to be used for the Manual Metal Arc
(MMA) process, Pst and dc values shall be evaluated according to the
procedures defined in the standard.