Sanitizing the Injector System
If the Injector Assembly is already assembled,
disassemble it before proceeding.
1. Prepare sanitizer solution by mixing half a
packet (1 oz) of Stera-Sheen® Green Label
with one gallon of warm water (108°F /
42°C) until dissolved. Pour approximately
16 oz. of sanitizer into a spray bottle.
2. Remove the o-rings from the spout adapter.
Submerge the Gear Box, nut, Gear
Cartridge, spout adapter, o-rings,
suspension bracket and Injector Head in
sanitizer solution and soak for 5 minutes.
3. Remove the cap and spray the cap and
syrup line manifold opening with sanitizer
solution. Allow them to sanitize for at least 5
minutes.
4. Place the 9-Tube Assembly and manifold
cap on a sanitary tray to dry. Remove the
parts from the sanitizer solution and place
them on the tray to air dry.
Assembling the Injector Assembly
1. Place the Gear Cartridge into the Gear Box
so that the gear teeth line up with the gear
inside the Gear Box.
2. Install the Injector Head onto the Gear Box
and rotate off-center to secure.
3. Insert the Drive Motor into the Gear Box so
that all four locking screws are fully seated.
Rotate the motor clockwise to secure.
Summary of Contents for STL-80SS
Page 2: ......
Page 9: ...6 PAGE INTENTIONALLY LEFT BLANK ...
Page 11: ...8 General System Overview Figure 1 ...
Page 13: ...10 Cabinet Continued Figure 2 ...
Page 17: ...14 Syrup Pump and Related Parts Figure 4 ...
Page 19: ...16 Sanitizer Pump and Related Parts Figure 5 ...
Page 23: ...20 Spare Parts Kit Figure 7 ...
Page 24: ...21 PAGE INTENTIONALLY LEFT BLANK ...
Page 36: ...33 PAGE INTENTIONALLY LEFT BLANK ...
Page 50: ...47 PAGE INTENTIONALLY LEFT BLANK ...
Page 73: ......
Page 74: ......