NOTE:
YOUR HANDS SHOULD BE CLEANED
AND SANITIZED BEFORE YOU PERFORM
THE FOLLOWING PROCEDURES.
NOTE:
THE FOLLOWING PROCEDURES
REQUIRE APPROVED, SERVICEABLE AND
SANITIZED TOOLS AND BRUSHES.
CONTACT WHITE GLOVE SERVICE FOR
RECOMMENDED SUPPLIES.
NOTE:
USE STERA-SHEEN® GREEN LABEL
SANITIZER AND DAWN® DISH SOAP MIXED
WITH WARM WATER (108°F / 42°C) FOR THE
FOLLOWING PROCEDURES. REFER TO
MANUFACTURER’S INSTRUCTIONS FOR
PROPER PREPARATIONS OF THESE
CLEANING AGENTS.
NOTE:
INSPECT ALL WEAR ITEMS AND
REPLACE IF NECESSARY.
Removing the Injector System
Follow these instructions to remove the Injector
System from the freezer during closing.
1. With a container under the dispensing
spout, press the FLUSH SPOUT button on
the Touch Panel to purge any remaining
product from the spout.
NOTE:
IF NO “FLUSH SPOUT” BUTTON IS
DISPLAYED ON THE SCREEN, YOU CAN
USE THE FLUSH SPOUT BUTTON IN THE
“FLUSH FUNCTIONS” SECTION OF THE
MAINTENANCE MENU.
2. Rotate the 9-Tube Assembly coupler until it
unlocks and is able to slide out of the
Injector Head syrup line opening.
3. Disconnect the Drive Motor cable from the
Drive Motor.
4. Remove the Gear Box nut. Rotate the
Injector Head locking collar until it unlocks
from the spout adapter and remove the
Injector Head from the adapter.
DAILY CLOSING PROCEDURES
Summary of Contents for STL-80SS
Page 2: ......
Page 9: ...6 PAGE INTENTIONALLY LEFT BLANK ...
Page 11: ...8 General System Overview Figure 1 ...
Page 13: ...10 Cabinet Continued Figure 2 ...
Page 17: ...14 Syrup Pump and Related Parts Figure 4 ...
Page 19: ...16 Sanitizer Pump and Related Parts Figure 5 ...
Page 23: ...20 Spare Parts Kit Figure 7 ...
Page 24: ...21 PAGE INTENTIONALLY LEFT BLANK ...
Page 36: ...33 PAGE INTENTIONALLY LEFT BLANK ...
Page 50: ...47 PAGE INTENTIONALLY LEFT BLANK ...
Page 73: ......
Page 74: ......