40
6. When all the syrup lines with replaced
flavors have been primed, go to “Flushing
Functions” in the Maintenance Menu and
press FLUSH SPOUT to clean the spout.
NOTE:
TO CHANGE THE FLAVOR BUTTONS
ON THE MENU SCREEN, GO TO THE
“SETUP TRAYS AND DISPENSE SPEEDS”
OF THE MAINTENANCE MENU AND PRESS
ANY FLAVOR DESPCRIPTION TO RENAME.
Replacing Injector Head O-Rings
The Injector Head o-rings are wear items and
will need to be replaced periodically. Always
keep spares of these items on hand in the
Spare Parts Kit for replacement.
1. Prepare detergent water by mixing several
drops of Dawn
®
dish soap with a gallon of
warm water (108°F / 42°C). Prepare
sanitizer solution by mixing half a packet (1
oz) of Stera-Sheen® Green Label with one
gallon of warm water (108°F / 42°C) until
dissolved.
2. Remove the worn o-rings from the Injector
Head. A small tool may be needed to
remove the two o-rings in the syrup line
opening.
3. Brush and clean all exposed surfaces of the
Injector Head with detergent water. Use a
small brush to ensure that the syrup orifices
are clear of any residual syrup.
4. Submerge the Injector Head and the new
replacement o-rings in sanitizer solution and
soak for at least 5 minutes.
5. Remove the o-rings and Injector Head and
place them on a sanitary tray to dry.
6. Place the larger o-ring into the groove on
the underside of the Injector Head.
Summary of Contents for STL-80SS
Page 2: ......
Page 9: ...6 PAGE INTENTIONALLY LEFT BLANK ...
Page 11: ...8 General System Overview Figure 1 ...
Page 13: ...10 Cabinet Continued Figure 2 ...
Page 17: ...14 Syrup Pump and Related Parts Figure 4 ...
Page 19: ...16 Sanitizer Pump and Related Parts Figure 5 ...
Page 23: ...20 Spare Parts Kit Figure 7 ...
Page 24: ...21 PAGE INTENTIONALLY LEFT BLANK ...
Page 36: ...33 PAGE INTENTIONALLY LEFT BLANK ...
Page 50: ...47 PAGE INTENTIONALLY LEFT BLANK ...
Page 73: ......
Page 74: ......