background image

Models: 

CC 206s 
CC 206c 
CC 208s 
CC 208c 
CC 208h

 

 

 

 

 

Owner

’s Manual

 

Compact Commercial Series 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for CC 206c

Page 1: ...Models CC 206s CC 206c CC 208s CC 208c CC 208h Owner s Manual Compact Commercial Series ...

Page 2: ......

Page 3: ...0 Control Disc 10 Control Disc Indicator 11 Lower Valving Sections 11 Tank Components 12 3 0 INSTALLATION Getting Started 13 Pre installation Review 13 KineticoPRO Compact Commercial Softener Installation 14 4 0 TROUBLESHOOTING Ten Steps to Determine the Problem 17 Hard Water 19 Frequent Regeneration 20 High Salt Consumption 20 Leaks 20 Salty Treated Water 21 Taste Color Odor 21 Iron Bleed through...

Page 4: ...o the equipment specifications section for specific instructions A caution icon will be used to present any information that may hold a potential hazard or concern during the installation use or maintenance of this product Should this information not be followed it may result in damage to this equipment and its surroundings Pinch point or crushing hazard Chemical hazard The warning icon will be us...

Page 5: ... operate at 150 F average and 160 F peak h high temperature This is a standard system upgraded to be compatible with high temperature operation 150 F average and 155 F peak The brining system is not included with the standard package A variety of brine tanks can be added as an option CC 206 2 6 x 13 tanks Part Number Model Description 11290A CC 206s Standard Compact Commercial Softener no brine ta...

Page 6: ...let Pipe Maximum Flow 50 psi inlet Maximum Flow 100 psi inlet 0 75 10 gpm 15 gpm 1 15 gpm 25 gpm 1 25 25 gpm 40 gpm 1 5 40 gpm 60 gpm 2 65 gpm 90 gpm 3 150 gpm 225 gpm 4 275 gpm 350 gpm Water Meter Size Maximum Flow 0 75 30 gpm 1 50 gpm 1 5 100 gpm 2 170 gpm 3 400 gpm Continuous Flow Continuous flow can take on many different definitions For the application of our equipment continuous flow is defi...

Page 7: ... 25 28 23 27 23 27 Disc 6 15 23 15 23 29 33 27 32 27 32 Disc 7 18 27 18 27 33 37 30 35 30 35 Disc 8 20 30 20 30 37 42 35 40 35 40 Meter Gearing Disc 1 583 gal 583 gal 732 gal 732 gal 732 gal Flow Range 0 3 9 1 gpm 0 3 9 1 gpm 0 3 10 2 gpm 0 3 10 2 gpm 0 3 10 2 gpm Hardness Removed in compensated gpg Micro Nozzle 0 5 lb brining 1 0 lb brining Disc 1 20 20 30 30 30 Disc 2 30 30 40 40 40 Disc 3 40 40...

Page 8: ...depend on the nozzle used with the system Most units incorporate the half louver nozzle This nozzle gives a highly accurate and wide range of flow metering capability If an alternative nozzle is used a different meter volume per 360º on the water meter will result The Half Louver Nozzle is standard with all CC Systems Micro Half Louver Full Louver Open Louver Part Number 10880B 11018 11019 15653 M...

Page 9: ...y Dosing 1 2 3 4 5 6 7 8 1 0 lb 4 568 grains 4 568 g lb 2 5 lb ft3 5 10 15 20 25 29 33 37 1 4 lb 5 212 grains 3 723 g lb 3 5 lb ft3 6 12 18 23 28 33 37 42 Gallons Regeneration 732 366 244 183 146 122 105 92 Flow during regeneration 15 psig 10 2 10 2 10 2 10 2 10 2 8 3 6 7 5 5 Compensated hardness in gpg Hardness 3 x Fe in mg L CC 208c h Alternating Operation with Central Brining Meter Disc Selecti...

Page 10: ... regeneration chamber As the regeneration turbine spins it drives the regeneration drive pawl which advances the control disc Jet Regeneration During the regeneration water is used by the valve to control the sequence For units equipped with Jet Regeneration a 0 2 gpm regeneration flow control is used to limit the amount of water used In addition to this small flow control the regeneration nozzle ...

Page 11: ...r the Remote Tank and one set for the Main Tank For each media tank there is an Inlet Outlet Drain and Check Stem valve also a downflow rinse valve on DFFR enabled systems The Inlet Outlet and Drain valves are all servo valves controlled by the control disc The Check Stems are simple one way valves check valves Together these valves control the flow of water into and out of each media tank during ...

Page 12: ...ashing or flowing out of the tanks Riser Tube A riser tube is used to connect the lower distributor to the control valve The riser tube is 1 0 in diameter Distributors The lower distributors for all CC units are an integrate distributor with the tank The flat plate stainless steel distributor provides for maximum flow distribution and strength Media High capacity non solvent cation resin is used i...

Page 13: ...l result It is recommended that a WQA certified installer perform the installation Failure to install the system as instructed will void the warranty Proper ventilation MUST be provided when using PVC cleaner or glue A ladder should be used for all work overhead that would be beyond your natural reach If working continuously at a height of six feet or more the appropriate safety devices must be em...

Page 14: ...ean grade of salt is strongly recommended DO NOT use rock salt This unit will NOT make potable water from a non potable source Read all steps guides and rules carefully before installing and using the KineticoPRO Softener KineticoPRO CC Series Softener Installation 1 Determine location to install equipment Make sure that the unit will be on a flat surface Test water to confirm unit is properly siz...

Page 15: ...ve and allowing water to rinse out any debris in the lines 6 An air gap must be provided for all drain lines Check local and state plumbing codes for the proper setup of drain line air gaps 7 Run a drain line to discharge point FOLLOW STATE AND LOCAL CODES Before connecting unit check for any obstructions or kinks Apply Teflon tape to pipe threads on side of softener valve and install the two fitt...

Page 16: ...s along the back of the brine well away from the brine drum wall The 3 8 bent tube snaps into a notch and extends from the brine drum about 1 Do not drop the brine valve into the drum Dropping may lower the float cup resulting in an improper setting Brine Valve Settings Unit Brine Setting 206 Cabinet 208 Cabinet 12x20 18 x 35 CC 206 0 5 lb Setting 5 X 1 7 X CC 206 1 0 lb Setting 6 X 1 5 7 1 7 CC 2...

Page 17: ...s there bridged salt in the drum Is the prefilter clogged Look for obvious installation mistakes Is the meter disc and salt setting correct according to raw water Is the by pass disc correct Are the inlet and outlet lines reversed Drain installation Are there any kinks restrictions or T s from other appliances using water Is the unit running water to drain Refer to the section for problems and sol...

Page 18: ...imate metering rate for all models is shown below 8 Measure water pressure Low water pressure can cause hard water and or salty water Measure the water pressure 1 Adapt a pressure gauge to the brine fitting port on Level 3 2 Turn on cell 3 Place either tank in the backwash portion of cycle a Did the pressure drop below 15 psi at the brine fitting The Kinetico valve requires a minimum of 15 psi for...

Page 19: ...creen 4 Short salting The grid system allows a water level no more than 1 above the grid If the cabinet is not level it may exceed this Level the cabinet 5 Bridged salt in the cabinet Salt has solidified in the cabinet Carefully move the salt around to break up the mass of solidified salt 6 The by pass is open An open by pass allows water to flow around the system without any treatment at all Clos...

Page 20: ...he section entitled Frequent Regeneration See the section entitled Frequent Regeneration 2 Water level in the brine drum is too high The brine valve is set wrong or non conforming The brine valve or the brine drum is dirty The brine valve leaks Verify the brine valve setting Replace non conforming brine valve Clean brine valve and drum Tighten the connectors on the brine valve Leaks Problem Reason...

Page 21: ...ial that finds its way into the media tanks may be collected around the upper distributors during backwash clogging them Clean upper distributors Install a prefilter 6 Water level in the cabinet is too high The brine valve is set wrong or non conforming Verify the brine valve setting Replace non conforming brine valve Taste Color Odor Problem Reason Solution 1 Treated water has a metallic or iron ...

Page 22: ...ter softeners start by testing the drain water If the drain water is hard the tank currently in service has a problem with its drain valve If the drain water is soft start with number 1 below Problem Reason Solution 1 The balance piston O ring is not seated properly Water will leak past an improperly seated balance piston O ring and out the drain Depress the actuator several times to seat the O ri...

Page 23: ...bing The brine line and or the brine valve are not air checked Run through an entire cycle to allow the air to escape Identify air leaks in the plumbing and fix them Identify and replace the faulty part s Unit Sticks in Cycle Problem Reason Solution 1 The unit sticks in regeneration or backwash cycle The regeneration flow path is plugged at the regeneration nozzle or flow control The regeneration ...

Page 24: ...10 Disc 8 1511 Balance Piston O ring 1070 Balance Piston 14927 Balance Piston Spring 5448 Control Disc 4689 central brining 4700A No Back Pawl 7097 Meter Drive Pawl 7014 Meter Drive Pawl Spring 7010A Regen Start Pawl 1783 Eccentric Pin 1520 Level 1 Filter 10781 Support Pin 1023 Regen Drive Pawl 5511 Eccentric Pin 1520 Regen O ring 2657 Level 1 Screw 8 1830 Level 1 Seal Red LSR 8471 Level 1 Assembl...

Page 25: ...6 1527 Gear 7 1528 Turbine 8 jet 11011A Turbine PP9 9258 Turbine 10 jet 8781F Stem Gear 1521 Washers 1773 E ring 1022 Meter Turbine Retainer 7859 Gear Alignment Clip 11902B Gearing Micro Nozzle 0 05 gpm 5 gpm 10880B Louver Nozzle CC 206s CC 206c h CC 208s CC208c h 0 3 25 gpm 11018 Full Louver Nozzle 0 7 40 gpm 11019 Open Louver Nozzle 1 1 50 gpm 15653 Nozzles 1 or 1 Brass Solder 7841 complete kit ...

Page 26: ...Level 5 check stem 7866B 7874B Drain Valve Seal 8193A 7869 Vent Tube 1480 Level 2 8784D Brine Flow Control CC 206 0 3 gpm 10546 CP 208 0 4 gpm 5156 Level 2 Seal Red LSR 8630 Level 2 Level 5 Drain Elbow 1850 NPT x Tube Level 3 8915C Brine Elbow 1840 3 8 NPT x 3 8 Tube Level 3 Seal Red LSR 8631 Venturi Throat Dark Blue 2294 Venturi O ring 1460 Regeneration Flow Control 0 2 gpm 9183B Level 3 Level 4 ...

Page 27: ... x Tube Union 9210 Bent Tube CC 206c h 11549A 12x20 Brine Tank 7899 18x35 Brine Tank 7802 Well Cover CC 206c 10087B CC 208c h 10087B 12x20 18x35 7815A Rod Lock 7796 12x20 18x35 7796 Float Cup 10699 12x20 18x35 7821 Float Cup Grommet 7789 Float Cup Retainer 7820A Rod Guide CC 206c h 10698 CC 208c h 10698 12x20 18x35 7798 Adjuster Tube CC 206c CC208c h 10091 12x20 18x35 7787B Brine Valve Assembly 77...

Page 28: ...neticoPRO Logo 17526 Valve Lock Included w Cabinet Screw 1010 Drain Tube 11517 Brine Tube 11516 Brine Well 11709 Grid Plate 11510A Bulkhead 11515 Caster Washer 11527 Caster 11977A Caster Wheel Install Kit 11526A Rubber Feet 11698 Screws for Rubber Feet 11698 11699 CC 208c h Brine Tank Lid 5662A Grid Plate Complete 8705 Grid Plate 8700 Grid Support 8706 Tank 11853 Brine Well 7918A Overflow Nut 1139...

Page 29: ...29 Notes ...

Page 30: ...Compact Commercial Softener Owner s Manual 30 Notes ...

Page 31: ......

Page 32: ...Owner s Manual Compact Commercial Series 2021 Kinetico Incorporated Corporate Headquarters 10845 Kinsman Road Newbury Ohio 44065 www KineticoPRO com Product No 11524H Rev 06 02 2021 ...