Compact Commercial Softener Owner
’s Manual
8
O
PERATING
S
PECIFICATIONS
System Operation
KineticoPRO Water Softeners use a twin tank design to assure that treated water is
always available. When one tank regenerates, the other supplies treated water. The
Kinetico Valve controls when each tank is in service, when each tank must be
regenerated and the regeneration of each tank.
Level 1 Operation
Level 1 assembly consists of three chambers: inlet, outlet and regeneration chambers.
Hard water enters the inlet chamber and travels to the media tank where it is treated.
Treated water moves from the media tank to the outlet chamber. Contained in the outlet
chamber is a water meter turbine, which turns only when water is used. Gears connect
the water meter turbine to the water meter disc.
The system’s meter gearing is defined as
the volume of processed water needed to turn the water meter disc 360º.
Flow Nozzle
Accuracy and range of the flow meter will depend on the nozzle used with the system. Most units incorporate the
half louver nozzle. This nozzle gives a highly accurate and wide range of flow metering capability. If an
alternative nozzle is used, a different meter volume per 360º on the water meter will result. The Half Louver
Nozzle is standard with all CC Systems.
Micro
Half Louver
Full Louver
Open Louver
Part Number
10880B
11018
11019
15653
Min. Flow Range
0.05 gpm
0.3 gpm
0.75 gpm
1.10 gpm
Max. Flow Range
5.00 gpm
25.00 gpm
40.00 gpm
50.00 gpm
Meter Gearing
Depending on the gear stack used, the volume of water per 360º on the water meter will change. Some of the
gear stacks used are listed.
Gearing
Micro
(0.05-0.15 gpm)
Micro
(0.15-0.50 gpm)
Half Louver
Full Louver
Open Louver
2-2-2-3
36
146
342
760
1291
2-2-1-5
40
163
381
848
1440
2-2-7-6*
61
250
600*
1303
2213
2-2-3-4
69
282
657
1470
2497
2-1-5-4**
77
315
750**
1639
2785
2-7-6-4
119
484
1,119
2520
4280
2-3-4-4
134
546
1,253
2843
4829
1-5-4-4
149
609
1,408
3171
5386
7-23-23-6
180
735
1,715
3829
6504
7-6-4-4
230
936
2,168
4873
8279
3-4-4-4
289
1056
2,431
5498
9340
* Standard CC 206 Models
** Standard CC 208 Models
Inlet
Regeneration
Outlet