![VNS G-413 User Manual Download Page 7](http://html1.mh-extra.com/html/vns/g-413/g-413_user-manual_1043369007.webp)
G413 User Guide Document: G41302
-------------------------------------------------------------------------------------------------------------------------------------------
7
11)
Programmable EDID:
preset 13 EDID programmable EDID setting to optimize input
resolution. Programmable EDID has below resolution range: H: 1024-3840, V: 720-2400
12)
LCD burn-in mark protection:
Auto image position shift to prevent LCD from burn-in mark.
13)
PIP function:
Picture in Picture from two selected signal sources with flexible position and image
size (320*180 up to 1920*1200). PIP image can be further adjusted by Overlap function to get
various size and shape.
14) Main and PIP image can be swapped to cover full screen across entire video wall.
15)
POP function:
Image Side by Side display with full screen or maintain original aspect ratio. Two
POP contents can be displayed on LCDs at RH/LH or up/down positions with monitor at landscape
direction.
16)
System setup:
User can setup the system through IR remote controller, USB or Ethernet. User can
connect G413 to WiFi router and execute system setup and control via WiFi through any device
connected with WiFi router. WebGui and Galign2 PC tool is available for Ethernet operation.
17)
System control:
user can control G413 through IR remote controller, USB, RS232 and Ethernet.
18)
Auto power on/off control
: When no input signal is detected, GeoBox can auto-turn off output
signal. Once input signal is detected, it will auto-turn on GeoBox and send out signal again. It is
convenient for system power on/off control.
19)
Selectable background color
: When adjusting aspect ratio, user may see some blank background
in the video wall. User can select background color by OSD.
20)
Custom settings
: Up to 10 different display modes settings in the same signal source can be
stored. 5 display Profiles with different input source and PIP/POP setting can be stored. User can
recall at any time through remote controller, RS232, USB or Ethernet.