[Position]: to shift complete image in each G413 to let image match together in multiple unit cascade
application.
The maximum video wall can be up to 15x15=225 units of G413. If each G413 is connected with 4x
LCDs, then theoretically maximum number of LCD displays can be up to 60x60=3600 LCDs from
single signal source.
15.4.1 [Zoom]: Split Image for cascade application
A case study for multiple G413 cascade is described in section 11.2. Please check.
User can set both Horizontal and Vertical Zoom value based on the array of the Display Units.
In below example, each number means one Display Units (4 LCDs) and also means one G413.
Example A:
Example B:
15.4.2 [Pan]: Assign image for each G413 in cascade application
3x1 three G413 horizontal cascade:
--Horizontal Zoom=3
--Vertical zoom=1
1) G413 is designed with 4 LCDs as one
Display Unit
2) Zoom function is to split the source image
for different Display Unit in multiple G413
cascade applications.
In 3x3 nine G413 cascade:
--Horizontal Zoom=3
--Vertical Zoom=3