125
Parameter
Description
Ping Check:
Enables the Ping Check function to detect the connection between PoE
port and power device. Disable will turn off the detection.
Port:
This is the logical port number for this row.
Ping IP Address:
The PD’s IP Address the system should ping.
Interval Time (sec):
Device will send checking message to PD each interval time.
Retry Time:
When PoE port is unable to ping the PD, it will retry to send detection
again. After the third try, it will trigger failure action.
Failure Log:
Failure loggings counter.
Failure Action:
The action when the third fail detection.
Nothing
-
“Nothing” keeps pinging the remote PD but doesn’t do any
further actions.
Reboot Remote PD
-
Cuts off the power of the PoE port and forces the PD
to reboot.
Reboot time:
When PD has been rebooted, the PoE port restores power according
to the specified time.
Total Reset:
Reset the total value of the “Failure Log”.
Button:
Apply
-
Click “Apply” to apply the change.