5.
Undo screws
D
and pull out plate-
type heat exchanger
C
to the
front.
6.
Check the DHW connections for
scaling and, if required, replace the
plate-type heat exchanger.
7.
Check the heating water connec-
tions for contamination and, if
required, flush via central heating
return
G
(flushing system for
plate-type heat exchanger, see pri-
celist).
8.
Lubricate the new gaskets/seals.
Install in reverse order with new
gaskets.
Checking the outside temperature sensor (weather-compen-
sated control unit)
1.
Pull plug "X3" from the control unit.
2.
Test the resistance of the outside
temperature sensor across term-
inals "X3.1" and "X3.2" on the dis-
connected plug and compare it with
the curve.