Press the following keys:
1.
L
+
d
simultaneously for
approx. 2 s.
The subscriber check
has been initiated.
2.
a
/
b
for the required subscri-
ber.
3.
d
Check is enabled
"
Check
" flashes until its
completion.
The display and all key
illuminations for the
selected subscriber flash
for approx. 60 s.
4.
"
Check OK
" is displayed during
communication between both
devices.
or
"
Check not OK
" is displayed if
there is no communication
between both devices. Check the
LON connection.
5.
Repeat points 2 and 3 to check
further subscribers.
6.
L
+
d
simultaneously for
approx. 1 s.
The subscriber check is
completed.
Instructing the system user
The system installer must hand the operating instructions to the system user
and instruct him/her in the operation of the system.
Scanning and resetting the "Service" display
The red fault indicator flashes when the limits set via coding address "21" and
"23" have been reached. The programming unit display flashes:
&
On a constant temperature control unit:
The defaulted hours run or the defaulted interval with clock symbol "
u
" (sub-
ject to setting)
&
On a weather-compensated control unit:
"Service"
Note
Set code "24:1" and then code "24:0" if a service is carried out before the ser-
vice display is shown; the set service parameters for hours run and interval are
then reset to 0.
Press the following keys:
1.
c
The service scan is active.
2.
a
/
b
Scan service messages.
Further details regarding the individual steps
(cont.)
51
Commissioning, inspection, maintenance
5592
817
GB
Service
Summary of Contents for VITOPEND 200
Page 12: ...Opening the control unit casing 12 Installation sequence 5592 817 GB...
Page 16: ...Fitting the programming unit into the control unit 16 Installation sequence 5592 817 GB...
Page 17: ...Fitting the front panel 17 Installation sequence 5592 817 GB Installation...
Page 113: ...Connection and wiring diagram internal connections 113 Designs 5592 817 GB Service...
Page 119: ...Parts lists cont 119 Parts lists 5592 817 GB Service...
Page 120: ...Parts lists cont 120 Parts lists 5592 817 GB...
Page 121: ...Parts lists cont 121 Parts lists 5592 817 GB Service...
Page 122: ...Parts lists cont 122 Parts lists 5592 817 GB...
Page 130: ...130 5592 817 GB...
Page 131: ...131 5592 817 GB...