Coding in the delivered condition
Possible change
Slope A1/M2
d3:14
Heating curve slope =
1.4 (only for weather-
compensated control
units)
d3:2
to
d3:35
Heating curve slope ad-
justable from 0.2 to 3.5
(see page 45)
Level A1/M2
d4:0
Heating curve level = 0
(only for weather-com-
pensated control units)
d4:
–
13
to
d4:40
Heating curve level ad-
justable from
–
13 to 40
(see page 45)
Code 2
Calling up code 2
Note
&
On weather-compensated control
units, codes are displayed as plain
text.
&
Codes that are irrelevant due to the
system equipment level or the set-
ting of other codes will not be dis-
played.
Press the following keys:
1.
L
+
G
simultaneously for
approx. 2 s.
2.
d
to confirm.
3.
a
/
b
for the required coding
address; the address
flashes.
4.
d
to confirm; the value
flashes.
5.
a
/
b
for the selected value.
6.
d
to confirm; the display
briefly shows
"
accepted
" (for
weather-compensated
control units); the
address flashes again.
7.
a
/
b
for the selection of
further addresses.
8.
L
+
G
press simultaneously for
approx. 1 s; code 2 is
terminated.
Summary
The coding addresses are grouped according to the following
function areas
.
The respective function area is shown on the display.
Code 1
(cont.)
55
Coding
5592
817
GB
Service
Summary of Contents for VITOPEND 200
Page 12: ...Opening the control unit casing 12 Installation sequence 5592 817 GB...
Page 16: ...Fitting the programming unit into the control unit 16 Installation sequence 5592 817 GB...
Page 17: ...Fitting the front panel 17 Installation sequence 5592 817 GB Installation...
Page 113: ...Connection and wiring diagram internal connections 113 Designs 5592 817 GB Service...
Page 119: ...Parts lists cont 119 Parts lists 5592 817 GB Service...
Page 120: ...Parts lists cont 120 Parts lists 5592 817 GB...
Page 121: ...Parts lists cont 121 Parts lists 5592 817 GB Service...
Page 122: ...Parts lists cont 122 Parts lists 5592 817 GB...
Page 130: ...130 5592 817 GB...
Page 131: ...131 5592 817 GB...