Venting the heating system
1.
Start the control unit.
2.
Activate the venting program via
code "2F:1".
Note
To call up coding level 1 and for
setting the coding address, see
page 53.
For function and sequence of the
venting program, see page 106.
Whilst the venting program is run-
ning, the display shows "
EL
"
(Vitotronic 100) or "
Entlüftung
"
(venting) (Vitotronic 200).
3.
Check the system pressure.
Setting the time and date (if required)
–
only for weather-
compensated control units
Note
&
During commissioning, or after a
prolonged time out of use, it may be
necessary to reset the time and
date, if the time flashes in the dis-
play.
&
During commissioning these terms
appear in German (delivered condi-
tion):
Time (see step 1)
Date (see step 2)
Press the following keys:
1.
a
/
b
for the current time.
2.
d
to confirm; "
Datum
" (date)
is displayed.
3.
a
/
b
for the current date.
4.
d
to confirm.
Further details regarding the individual steps
(cont.)
21
Commissioning, inspection, maintenance
5592
817
GB
Service
Summary of Contents for VITOPEND 200
Page 12: ...Opening the control unit casing 12 Installation sequence 5592 817 GB...
Page 16: ...Fitting the programming unit into the control unit 16 Installation sequence 5592 817 GB...
Page 17: ...Fitting the front panel 17 Installation sequence 5592 817 GB Installation...
Page 113: ...Connection and wiring diagram internal connections 113 Designs 5592 817 GB Service...
Page 119: ...Parts lists cont 119 Parts lists 5592 817 GB Service...
Page 120: ...Parts lists cont 120 Parts lists 5592 817 GB...
Page 121: ...Parts lists cont 121 Parts lists 5592 817 GB Service...
Page 122: ...Parts lists cont 122 Parts lists 5592 817 GB...
Page 130: ...130 5592 817 GB...
Page 131: ...131 5592 817 GB...