Coding
Internal cir-
culation
pump
Heating circuit
pump
Heating circuit
without mixer
Heating circuit pump
Heating circuit with
mixer
12
OFF
OFF
Control funct.
13
OFF
OFF
Control funct.
14
OFF
OFF
OFF
15
OFF
OFF
OFF
Coding in the delivered condition
Possible change
Boiler/burner
34:0
Influence of the signal
"External demand" on
the circulation pumps:
All pumps in control
function
34:1
to
34:23
Influence of the signal
"External demand" on the
circulation pumps: see
the following table
Coding
Internal circula-
tion pump
Heating circuit
pump
Heating circuit
without mixer
Heating circuit
pump
Heating circuit with
mixer
0
Control funct.
Control funct.
Control funct.
1
Control funct.
Control funct.
Control funct.
2
Control funct.
Control funct.
OFF
3
Control funct.
Control funct.
OFF
4
Control funct.
OFF
Control funct.
5
Control funct.
OFF
Control funct.
6
Control funct.
OFF
OFF
7
Control funct.
OFF
OFF
8
OFF
Control funct.
Control funct.
9
OFF
Control funct.
Control funct.
10
OFF
Control funct.
OFF
11
OFF
Control funct.
OFF
12
OFF
OFF
Control funct.
13
OFF
OFF
Control funct.
14
OFF
OFF
OFF
15
OFF
OFF
OFF
16
ON
Control funct.
Control funct.
17
ON
Control funct.
Control funct.
18
ON
Control funct.
OFF
Code 2
(cont.)
58
Coding
5592
817
GB
Summary of Contents for VITOPEND 200
Page 12: ...Opening the control unit casing 12 Installation sequence 5592 817 GB...
Page 16: ...Fitting the programming unit into the control unit 16 Installation sequence 5592 817 GB...
Page 17: ...Fitting the front panel 17 Installation sequence 5592 817 GB Installation...
Page 113: ...Connection and wiring diagram internal connections 113 Designs 5592 817 GB Service...
Page 119: ...Parts lists cont 119 Parts lists 5592 817 GB Service...
Page 120: ...Parts lists cont 120 Parts lists 5592 817 GB...
Page 121: ...Parts lists cont 121 Parts lists 5592 817 GB Service...
Page 122: ...Parts lists cont 122 Parts lists 5592 817 GB...
Page 130: ...130 5592 817 GB...
Page 131: ...131 5592 817 GB...