If an external heat source is present, it
can be used in conjunction with the
electric heater for drying buildings
using this setting.
Access
&
"
System settings
"
&
"
Program
"
&
"
Internal hydraulic
"
&
"Ext. HS for drying buildings"
(
YES/NO
)
Standard setting
YES
Setting range
YES/NO
Hysteresis, flow
The set flow temperature of the sec-
ondary circuit is determined by the
control unit in accordance with the
current heat demand.
The "
Hysteresis, flow
" setting
defines, at what difference from an
internally calculated set flow tempera-
ture one of the heat sources (heat
pump, electric heater) is switched ON
and OFF.
Access
&
"
System settings
"
&
"
Program
"
&
"
Internal hydraulic
"
&
"Hysteresis flow"
(
0
/
=
)
Standard setting
2.0 K
Setting range
0.5 to 5.0 K
Internal pump run-on
Secondary pump run-on, after the
heat pump or the electric heater has
stopped generating heat.
Access
&
"
System settings
"
&
"
Program
"
&
"
Internal hydraulic
"
&
"Off-carr. int. pump"
(
P
/
Q
)
Standard setting
02:00 min
Setting range
00:10 to
05:00 min
External heat source for drying buildings
94
Internal hydraulics control settings
55
92
901
GB
Summary of Contents for VITOCAL 300
Page 19: ...Connection diagram Open CLOSE System version 1 cont 19 Preparing for installation 5592 901 GB...
Page 22: ...Connection diagram Open CLOSE System version 2 cont 22 Preparing for installation 5592 901 GB...
Page 137: ...Control PCB 137 Connection and wiring diagrams 5592 901 GB Service...
Page 140: ...Parts lists cont 140 Parts lists 5592 901 GB...
Page 141: ...Parts lists cont 141 Parts lists 5592 901 GB Service...
Page 159: ...159 5592 901 GB...