A
Over/undervoltage in %
B
Phase asymmetry in %
C
Switching delay in s
D
Operating display ("Rel")
E
Fault display phase failure/phase
sequence ("Ph")
F
Fault display asymmetry ("Asy")
H
Fault display over/undervoltage
("<>U")
LEDs explained
&
LED "Rel" illuminates green:
All voltages and the rotating field
(clockwise) are healthy.
&
LED "Ph" illuminates red:
The relay has responded; the rotat-
ing field is anti-clockwise.
&
All LED's off:
One or several phases has/have
dropped out.
&
LED "<>U" illuminates red:
Incorrect voltage on one/several
phase(s).
&
LED "Asy" illuminates red:
Incorrect voltage on one/several
phase(s).