112
Row (brief
scan)
Field
1
2
3
4
5
6
9:
Heating circuit A1 (without
mixer)
Heating circuit M2 (with
mixer)
Heating circuit M3 (with mix-
er)
Remote con-
trol
0: Without
1: Vitotrol
200-A
2: Vitotrol
300-A
3: Vitotrol
200-RF
4: Vitotrol
300-RF
or
Vitocomfort
200
Software ver-
sion, remote
control
Remote con-
trol
0: Without
1: Vitotrol
200-A
2: Vitotrol
300-A
3: Vitotrol
200-RF
4: Vitotrol
300-RF
or
Vitocomfort
200
Software ver-
sion, remote
control
Remote con-
trol
0: Without
1: Vitotrol
200-A
2: Vitotrol
300-A
3: Vitotrol
200-RF
4: Vitotrol
300-RF
or
Vitocomfort
200
Software ver-
sion, remote
control
10:
(Only for KM-
BUS circula-
tion pumps)
Internal circulation pump
Heating circuit pump, heat-
ing circuit M2
Heating circuit pump, heat-
ing circuit M3
Variable
speed pump
0: Without
1: Wilo
2: Grundfos
Software ver-
sion, variable
speed pump
0: No variable
speed pump
0
0
0
0
11:
0
0
Software ver-
sion
Mixer exten-
sion, heating
circuit M2
0: No mixer
extension
0
Software ver-
sion
Mixer exten-
sion, heating
circuit M3
0: No mixer
extension
0
Checking outputs (actuator test)
1.
Press
OK
and
å
simultaneously for approx. 4 s.
2. "Actuator test"
The following relay outputs can be controlled subject to the system equipment level:
Display
Explanation
All actuators
OFF
All actuators have been switched off.
Base load
ON
Burner operates at min. output. Internal pump is switched on.
Full load
ON
Burner operates at max. output. Internal pump is switched on.
Output, internal
ON
Internal output
sÖ
enabled (internal circulation pump)
Output 21/28
ON
Internal output
sA
enabled (cylinder loading pump)
Valve
Heating
Diverter valve set to heating mode
Valve
Centre
Diverter valve in central position (filling/draining)
Valve
DHW
Diverter valve set to DHW heating
Htg circ pump HC2
ON
Output for heating circuit pump enabled (extension heating circuit with
mixer)
Mixer HC2
Open
Output for "Mixer open" enabled (extension heating circuit with mixer)
Mixer HC2
Close
Output for "Mixer close" enabled (extension heating circuit with mixer)
Htg circ pump HC3
ON
Output for heating circuit pump enabled (extension heating circuit with
mixer)
Diagnosis and service scans
Gas condensing module
(cont.)
5775 636 GB
Diagnosis
Summary of Contents for C3TB
Page 136: ...136 Troubleshooting Repairs gas condensing module cont 5775 636 GB Diagnosis ...
Page 143: ...143 Parts lists Heat cell assembly 5775 636 GB Components ...
Page 160: ...160 Parts not shown 0009 PCB IU100 B30 Parts lists Fuel cell assembly 5775 636 GB Components ...
Page 161: ...161 Parts lists Fuel cell assembly cont 5775 636 GB Components ...
Page 187: ...187 5775 636 GB ...