If possible, leave the fuel cell module and the gas con-
densing module on their pallet during handling.
Fuel cell module
■
When transporting the fuel cell module, keep it upright
at all times on the pallet or its base.
■
On delivery, check the tilt indicators on the packaging:
If the tilt angle on delivery is
≥
60°, reject the delivery
but notify Viessmann.
■
If possible, only remove the fuel cell module from its
pallet once it is at its final installation site. Undo the
screws and remove the transport locking plates.
Fig. 1
■
Never subject the fuel cell module to strong vibrations
or shaking.
■
For easier handling, the fuel cell module may be tilted
up to 90°. See following diagram. Store the fuel cell
module upright.
!
Please note
To prevent damage to the appliance, when
transporting up or down stairs, always keep
the underside of the appliance lower than the
top.
A
Fig. 2
A
Appliance top
Gas condensing module
!
Please note
Prevent damage to the appliance during han-
dling.
Never lay the gas condensing module on its
front or side, or subject it to pressure.
If space constraints make it necessary, the gas
condensing module can be split for handling.
See page 45 for an illustration of the necessary
measures.
Siting
Room height required: min. 2250 mm
The Vitovalor 300-P must be installed with the gas
condensing module downstream of the fuel cell mod-
ule in the flue gas flow direction.
Preparing for installation
Handling
5775 636 GB
Installation
Summary of Contents for C3TB
Page 136: ...136 Troubleshooting Repairs gas condensing module cont 5775 636 GB Diagnosis ...
Page 143: ...143 Parts lists Heat cell assembly 5775 636 GB Components ...
Page 160: ...160 Parts not shown 0009 PCB IU100 B30 Parts lists Fuel cell assembly 5775 636 GB Components ...
Page 161: ...161 Parts lists Fuel cell assembly cont 5775 636 GB Components ...
Page 187: ...187 5775 636 GB ...