107
Coding in the delivered condition
Possible change
A9:7
With pump idle time: heating circuit
pump "OFF" when set value is
modified by changing the operating
mode or changing the set room
temperature
A9:0
Without pump idle time
A9:1
to
A9:15
With pump idle time, adjustable from
1 to 15.
1 = short idle time
15 = long idle time
b0:0
For heating circuit with mixer and
remote control only:
Heating mode/reduced mode:
Weather-compensated
b0:1
Heating mode: Weather-compensa-
ted
Reduced mode: With room tempera-
ture hook-up
b0:2
Heating mode: With room tempera-
ture hook-up
Reduced mode: Weather-compen-
sated
b0:3
Heating mode/reduced mode: With
room temperature hook-up
b2:8
Only for heating circuit with mixer
and remote control. Operation with
room temperature hook-up must
be programmed for the heating cir-
cuit:
Room influence factor 8
b2:0
Without room influence
b2:1
to
b2:64
Room influence factor adjustable
from 1 to 64. The higher the value,
the greater the room influence.
b5:0
For heating circuit with mixer and
remote control only:
Without room temperature-de-
pendent heating circuit pump logic
function
b5:1
to
b5:8
Heating circuit pump logic function,
see the following table.
Parameter address
b5:...
With heating circuit pump logic function:
Heating circuit pump "OFF"
Heating circuit pump "ON"
1
RT
actual
>
RT
set
+ 5 K
RT
actual
< RT
set
+ 4 K
2
RT
actual
>
RT
set
+ 4 K
RT
actual
< RT
set
+ 3 K
3
RT
actual
>
RT
set
+ 3 K
RT
actual
< RT
set
+ 2 K
4
RT
actual
>
RT
set
+ 2 K
RT
actual
< RT
set
+ 1 K
5
RT
actual
>
RT
set
+ 1 K
RT
actual
< RT
set
6
RT
actual
>
RT
set
RT
actual
< RT
set
–
1 K
7
RT
actual
>
RT
set
–
1 K
RT
actual
< RT
set
–
2 K
8
RT
actual
>
RT
set
–
2 K
RT
actual
< RT
set
–
3 K
Coding in the delivered condition
Possible change
C5:20
Electronic minimum flow tempera-
ture limit 20 °C (only when operat-
ing at standard room temperature)
C5:1
to
C5:127
Minimum limit adjustable from 1 to
127 °C (limited by boiler-specific pa-
rameters)
C6:74
Electronic maximum flow tempera-
ture limit 74 °C (only for weather-
compensated control units)
C6:10
to
C6:127
Maximum limit adjustable from 10 to
127 °C (limited by boiler-specific pa-
rameters)
d3:14
Heating curve slope = 1.4
d3:2
to
d3:35
Heating curve slope adjustable from
0.2 to 3.5 (see page 88)
d4:0
Heating curve level = 0
d4:–13
to
d4:40
Heating curve level adjustable from
–
Codes
Coding level 2
(cont.)
5775 636 GB
Codes
Summary of Contents for C3TB
Page 136: ...136 Troubleshooting Repairs gas condensing module cont 5775 636 GB Diagnosis ...
Page 143: ...143 Parts lists Heat cell assembly 5775 636 GB Components ...
Page 160: ...160 Parts not shown 0009 PCB IU100 B30 Parts lists Fuel cell assembly 5775 636 GB Components ...
Page 161: ...161 Parts lists Fuel cell assembly cont 5775 636 GB Components ...
Page 187: ...187 5775 636 GB ...