125
Draining the fuel cell module on the heating water side
B
A
Fig. 94
1.
If these have not yet been actioned: Set service
mode (see page 75).
Note
The cooling process on the fuel cell module lasts
approximately 90 min.
!
Please note
If this waiting time is not observed,
there is a risk of scalding and damage to the
appliance.
2.
Place a shallow container of sufficient size (min.
5 l) below drain port
A
.
3.
Unscrew the filter from drain port
A
.
4.
Undo screw
B
approx. 1.5 turns.
Draining the system on the DHW side
B
A
Fig. 95
1.
Shut off the cold water connection.
Troubleshooting