25
4.
Bend the connection line to the position of the dia-
phragm expansion vessel. Never kink the connec-
tion line (min. bending radius 25 mm). Attach the
connection line with gasket to the diaphragm
expansion vessel.
5.
Mount the diaphragm expansion vessel on the wall
using the bracket supplied.
6.
Adjust the charge pressure in the diaphragm
expansion vessel to 0.9 bar (0.09 MPa).
Aligning the Vitovalor 300-P
2.
1.
8x
Fig. 19
1.
Align the fuel cell module flush with the front of the
gas condensing module. Temporarily reattach the
front panel for this purpose (see page 44).
2.
Align the gas condensing module and the fuel cell
module in their final installation location.
Installation sequence
Installing the Vitovalor 300-P
(cont.)
5775 636 GB
Installation