background image

The Professional’s Choice

SureFlow compact range:  
CTS3, CTS5 & CTS10

(1000-M)  (1000-C)  &   (1500pou)

Auto-Fill Catering Water Boiler

Installation And User Instructions

Summary of Contents for SureFlow Compact Series

Page 1: ...The Professional s Choice SureFlow compact range CTS3 CTS5 CTS10 1000 M 1000 C 1500pou Auto Fill Catering Water Boiler Installation And User Instructions ...

Page 2: ... FAULT DIAGNOSTICS 6 7 TECHNICAL SUPPORT 7 GUARANTEE 7 Introduction Dear Customer Congratulations on the purchase of your Instanta machine Your new water boiler is designed to give you years of trouble free service provided that the instructions contained in this manual are followed All new series Instanta products are energy efficient simple to operate and easy to service Find out more about Inst...

Page 3: ... supervised to ensure they do not play with the appliance Always disconnect the unit from the power supply and allow it to cool down before servicing The components in the draw off tap are subject to wear tear Check periodically at least every 12 months as part of a general maintenance routine We recommend that a spare tap spring tap washer or upper tap assembly are held in case of emergencies and...

Page 4: ...ggressive due to lack of minerals or Ions and in extreme cases can cause leaching and corrosion of pipes fittings and other metal parts within the appliance If the appliance is being fed by water treated by Reverse Osmosis we recommend that the water is tested regularly If you have any queries in respect please contact our customer services team We regret that Instanta cannot be held responsible f...

Page 5: ...g When the boiler reaches the correct temperature the GREEN LIGHT will show that the boiler is ready IMPORTANT NOTE In normal daily use the boiler may be used as soon as the GREEN LIGHT shows but on first install wait 15 minutes before starting to use Regular Daily Use Switch boiler on Wait for the GREEN LIGHT The water will then be at the correct temperature Dispense water via the lever tap CAUTI...

Page 6: ...eck in coming water is at minimum of 2 bar Flashing Red Safety Control has activated An internal component has failed See Safety Controls below Contact Instanta Technical Sup port Flashing Red Green Over boil safety switch tripped on initial heat up Faulty Element Boil dry safety control activated Re set required Isolate power to appliance Push in manual reset button remove back panel to access Ca...

Page 7: ...set In any of these events the indicator lamp will flash red or green or red and green If the problem reoccurs contact the Instanta Service Department 01704 502911 Service Technical Support Tel 01704 502911 To ensure your service enquiry is handled as efficiently as possible please have the following information available Brief description of problem Product Type model Serial Number label on right...

Page 8: ...INSTANTA LIMITED Canning Road Southport Merseyside PR9 7SN Tel 01704 501114 Fax 01704 501115 IB27 ISS 04 FM 36413 EMS 75807 ...

Reviews: