Installation [All Models]

The boiler must be installed on a horizontal work 
surface with sufficient strength to support its weight. 

Locate in an area where there is adequate space to 
use the boiler safely (e.g. free from risk of congestion 
and tripping hazards).

CONNECTION TO MAINS WATER SUPPLY:

 

Connect the WRAS approved water filling hose 
(3/4”BSP) to the inlet connection point on the back 
of the boiler and the other end to the mains water 
supply, via an accessible isolating tap with a ¾”BSP 
thread.

IMPORTANT: If micro-bore pipe is used instead of the 
inlet hose supplied, the size must be minimum OD 
3/8”(10mm).

The water supply must have a pressure not 
exceeding 7bar (96psi), and no lower than 2bar 
(28psi). 

NOTE: If your water pressure exceeds 7bar, fit a 
suitable pressure reduction valve.

*To meet WRAS installation requirements, an 
approved single-check valve providing backflow 
prevention protection, should be fitted at the point 

of connection between the water supply and the 
appliances.

NOTE: Water that has been treated by the Reverse 
Osmosis process can become aggressive (due to lack 
of minerals or Ions), and in extreme cases can cause 
leaching and corrosion of pipes, fittings and other 
metal parts within the appliance. 

If the appliance is being fed by water treated by 
Reverse Osmosis, we recommend that the water is 
tested regularly.

If you have any queries in respect, please contact our 
customer services team. 

We regret that Instanta cannot be held 
responsible for any machine malfunctions if the 
water pressure exceeds that stated. If in doubt, 
consult your water supply company

ELECTRICAL CONNECTION:

The boiler must be Earthed.

Your machine is supplied with a standard 13amp 
bonded plug with a 13amp fuse. 

Model

1000-C

1000-M

1500

Width

mm

218

218

243

Depth

mm

465

465

503

Height

mm

440 

400

610

Tap Clearance

mm

150

150

190

Power Rating

kW

3.0

2.25

3.0

Rapid draw-off 

Litres

5

3

10

Weight (Empty)

kg

8.9

8.4

13.2

Weight (Full)

kg

15.9

14

26.7

Water Inlet 

Pressure:

Bar

2 to 7

2 to 7 

2 to 7 

Technical Information

Outer casing and tank are constructed in type-304 and type-316 grade stainless steel.  
The tank is fully insulated with high-temperature polystyrene. 

The appliance has electronic control of the main functions. This means that the heating,  
filling and temperature are controlled precisely within given parameters.

4

Summary of Contents for SureFlow Compact Series

Page 1: ...The Professional s Choice SureFlow compact range CTS3 CTS5 CTS10 1000 M 1000 C 1500pou Auto Fill Catering Water Boiler Installation And User Instructions ...

Page 2: ... FAULT DIAGNOSTICS 6 7 TECHNICAL SUPPORT 7 GUARANTEE 7 Introduction Dear Customer Congratulations on the purchase of your Instanta machine Your new water boiler is designed to give you years of trouble free service provided that the instructions contained in this manual are followed All new series Instanta products are energy efficient simple to operate and easy to service Find out more about Inst...

Page 3: ... supervised to ensure they do not play with the appliance Always disconnect the unit from the power supply and allow it to cool down before servicing The components in the draw off tap are subject to wear tear Check periodically at least every 12 months as part of a general maintenance routine We recommend that a spare tap spring tap washer or upper tap assembly are held in case of emergencies and...

Page 4: ...ggressive due to lack of minerals or Ions and in extreme cases can cause leaching and corrosion of pipes fittings and other metal parts within the appliance If the appliance is being fed by water treated by Reverse Osmosis we recommend that the water is tested regularly If you have any queries in respect please contact our customer services team We regret that Instanta cannot be held responsible f...

Page 5: ...g When the boiler reaches the correct temperature the GREEN LIGHT will show that the boiler is ready IMPORTANT NOTE In normal daily use the boiler may be used as soon as the GREEN LIGHT shows but on first install wait 15 minutes before starting to use Regular Daily Use Switch boiler on Wait for the GREEN LIGHT The water will then be at the correct temperature Dispense water via the lever tap CAUTI...

Page 6: ...eck in coming water is at minimum of 2 bar Flashing Red Safety Control has activated An internal component has failed See Safety Controls below Contact Instanta Technical Sup port Flashing Red Green Over boil safety switch tripped on initial heat up Faulty Element Boil dry safety control activated Re set required Isolate power to appliance Push in manual reset button remove back panel to access Ca...

Page 7: ...set In any of these events the indicator lamp will flash red or green or red and green If the problem reoccurs contact the Instanta Service Department 01704 502911 Service Technical Support Tel 01704 502911 To ensure your service enquiry is handled as efficiently as possible please have the following information available Brief description of problem Product Type model Serial Number label on right...