background image

 

 

COD. 79101EN.00 

 

11/2013 

 

 
 

 

BIOSELF 

MULTIFUEL BOILER 

 
 

USER AND INSTALLATION MANUAL 

 

 
 
 
 

 

Summary of Contents for BIOSELF

Page 1: ...COD 79101EN 00 11 2013 BIOSELF MULTIFUEL BOILER USER AND INSTALLATION MANUAL...

Page 2: ...COD 79101EN 00 11 2013 2...

Page 3: ...COD 79101EN 00 11 2013 3 LASIAN Tecnolog a del Calor S L gives thanks for trust in us THANKS FOR PURCHASING THIS PRODUCT...

Page 4: ...COD 79101EN 00 11 2013 4...

Page 5: ...of boilers for production of heating and A C S brand LASIAN In its different models BIOSELF 18 kW BIOSELF 24 kW WE HEREBY DECLARE under our sole responsibility that the above mentioned products are m...

Page 6: ...ls of the product Bold text requires particular attention Text in italics is used to draw your attention to other paragraphs in this manual or any additional explanation SYMBOLS USED IN THE MANUAL SYM...

Page 7: ...8 USE OF EXTERNAL CHIMNEY 19 4 9 EXTERNAL CHIMNEY 19 4 10 FRESH AIR INTAKE 21 4 11 MINIMUM DISTANCES FRESH AIR INTAKE 21 5 CONNECTIONS 22 5 1 ELECTRICAL CONNECTION 22 5 2 HYDRAULIC CONNECTION 22 6 USE...

Page 8: ...33 7 9 SAFETY TEMPERATURE LIMITER AND ROOM THERMOSTAT 34 8 WARNINGS AND MAINTENANCE 35 8 1 DOOR OPENING 35 8 2 DISPOSAL OF ASHES 35 8 3 BRAZIER CLEANING 35 8 4 ASH PAN CLEANING 35 8 5 COMBUSTION CHAM...

Page 9: ...chimney The power cable must be accessible after the installation of the boiler To start the boiler refer to chapter FUEL Never use liquid fuels to start the boiler Provide sufficient ventilation dur...

Page 10: ...of it to the service center Given the importance of the label we recommend installing the boiler respecting the distances so that it is always visible MODEL BIOSELF 18 kW BIOSELF 24 kW Nominal thermal...

Page 11: ...AND COMPONENTS MODELS BIOSELF 18 24 kW BIOSELF 18 24 kW 2 1 7 6 4 5 3 9 8 COMPONENTS 1 Control panel 2 80 Flue duct 3 Safety valve 4 male discharge 5 male return 6 Air intake 7 Electrical outlet 8 Hop...

Page 12: ...on of these programs can be found in chapter 8 Operation of the control panel in the paragraph 8 6 ATTENTION The boiler is provided with two burners one for the pellets and shredded almond shell combu...

Page 13: ...the packaging plastic bags polystyrene etc that could be potentially dangerous and dispose according to the existing laws 4 3 DOMESTIC FIRE PREVENTION The installation and use of the boiler must compl...

Page 14: ...st always be guaranteed INSTALLATION IN ANGLE mm INSTALLATION TO WALL mm Safety distance of the flammable material mm minimum distance air from flammable posterior wall P 400 minimum distance air from...

Page 15: ...heat sensitive or flammable floors is necessary to use a floor protection eg Steel sheet marble or tiles Whatever type of protection is chosen it must protrude at least 300 mm from the front and at le...

Page 16: ...h appliance must have its flue duct with a section equal to or greater than the diameter of the flue outlet duct of the boiler and a height of not less than that declared See table in paragraph 4 7 2...

Page 17: ...ENGTHS Pipes of painted aluminium clad steel minimum thickness of 1 5 mm stainless steel Aisi 316 or enameled steel minimum thickness of 0 5 mm with a nominal diameter of 80 mm can be used for pipes w...

Page 18: ...ing in cement 50 180 200 Wall or ceiling in brick 30 140 160 4 7 4 USE OF A TRADITIONAL TYPE CHIMNEY If you wish to use an existing chimney it is strongly recommended that you have it checked by a pro...

Page 19: ...tion of not less than twice of the flue pipe section The chimney which emerges from the ridge or that remains in contact with the outside e g the case of an open roof must be covered with brick elemen...

Page 20: ...Fig 2 Pitch of the roof Horizontal width of reflux area from ridge axis A m Minimum height of outlet from roof Hmin Z 0 50m Height of reflux area Z m 15 1 85 1 00 0 50 30 1 50 1 30 0 80 45 1 30 2 00...

Page 21: ...tion The air flow can also be obtained from an adjacent room to the place of the installation provided this air flows freely through permanent apertures that cannot be closed and communicate with the...

Page 22: ...visable to remove the cable from the boiler Maximum electrical absorption while ignition 6 min 490 Wat Electrical absorption Wat 120 Wat Voltage and supply frequency 230 V 50Hz By law the installation...

Page 23: ...y civil or criminal liability If during the ignition phase this does not occur and you notice a lot of smoke in the combustion chamber turn off the boiler and replace the fuel as the humidity could be...

Page 24: ...ition must take place the auger motor starts working again for a defined time The transition to the next phase is permitted when the fumes temperature exceeds the threshold and during the next 90 seco...

Page 25: ...o switch off the boiler you need to wait Similarly if it is in the shutdown phase the ignition cannot be forced again 6 13 STANDBY The boiler pass from the ON state to the STANDBY state in the followi...

Page 26: ...ion the display shows the following information on the screen During the operation phase the screen shows the power of the boiler from 1 to 6 Using and the power of the boiler can be increased or decr...

Page 27: ...to enter the submenu Temp boiler It allows you to select the maximun temperature for the water boiler Use and to set the temperature The range goes from 10 C to 80 C Press SET to confirm and save or...

Page 28: ...gram mtwtfss days of the week from Monday to Sunday on00 00 time of activation off00 00 time of shutdown Below you can see an example of a weekly schedule Example From Monday to Friday the boiler star...

Page 29: ...utdown time for program 1 Timer01 pressing SET and the text off00 00 will stop flashing With the keys and you can select the time 14 00 and press SET to confirm it From now on the text off 14 00 will...

Page 30: ...days are selected press SET to confirm now the text MTWTFss will start flashing To pass to the next parameter press Now the text on00 00 is flashing Now we can choose the desired start up time for pro...

Page 31: ...the active day changes from lower case to capital letter and vice versa The days in capital letter will be included in the schedule on off of this program As you can see only the days Saturday and Su...

Page 32: ...SET and after we select the corresponding number of fuel with the keys and With the key SET we confirm the selection and with the key we exit without saving the modification FUEL PROGRAMS Combustible...

Page 33: ...uct See paragraph 8 8 MAINTENANCE ORDINARY Appears after 300 hours of operation To cancel the message with the boiler off press the button during a few seconds MAINTENANCE EXTRAORDINARY Appears after...

Page 34: ...ms press the key during 3 seconds wait another 3 seconds and press again the key during 3 seconds except the mantenimiento extraordinario alarm see paragrah 9 6 7 9 SAFETY TEMPERATURE LIMITER AND ROOM...

Page 35: ...mmable materials 8 3 BRAZIER CLEANING Never open the door of the boiler until the display shows the message OFF This boiler has an ash cleaning system but due to the fuel quality some incrustations ca...

Page 36: ...ing the screw situated on the top of the frontal element then disengage the three pieces It is also necessary to take out the cover situated just below the brazier see Fig 3 unscrewing the screw that...

Page 37: ...mm thick ceramic glass resistant to a thermal shock of 750 C The glass can only break due to a strong impact or misuse Do not shake the door or hit the glass If the glass breaks avoid turning on the b...

Page 38: ...COD 79101EN 00 11 2013 38...

Page 39: ...s of the heating systems in particular for products with integrated heating system for water Insufficient air input grilles for the combustion BIOMASS BOILER OR SOLID FUELS Fuels with a moisture conte...

Page 40: ...COD 79101EN 00 11 2013 40...

Page 41: ...COD 79101EN 00 11 2013 DATE WORKING HOURS INTERVENTION TAS SIGNATURE USER SIGNATURE...

Page 42: ...COD 79101EN 00 11 2013 42 DATE WORKING HOURS INTERVENTION TAS SIGNATURE USER SIGNATURE...

Page 43: ...COD 79101EN 00 11 2013 43 DATE WORKING HOURS INTERVENTION TAS SIGNATURE USER SIGNATURE...

Page 44: ...unit and for manufacturing defects NOTE The manufacturer reserves the right to make product changes without notice always maintaining the technical and essential service characteristics to fulfill th...

Reviews: