Note that
Alt Ramp
and
Alt Ramp2
work together to choose the ramp, based on the values in the following chart:
726 MOL Polarity
Default: NO Operate
Range: n/a
Level 2
This parameter sets the Motor Overload input polarity. The following data values may be assigned to this parameter:
Parameter Value Description
NC Operate
A normally closed connection allows the unit to operate; the drive faults when the connection opens.
NO Operate
A normally open connection allows the unit to operate; the drive faults when the connection closes.
740 Thres 1 Select
Default: 15 (Curr High)
Range: n/a
Level 2
This parameter selects the type of threshold to be used for Threshold 1.
Parameter Value Description
Parameter Value Description
0
Vin 1 High
11
Load In
1
Vin 1 Low
12
Power High
2
Vin 1 In
13
Power Low
3
Vin 2 High
14
Power In
4
Vin 2 Low
15
Curr High
5
Vin 2 In
16
Curr Low
6
Cin High
17
Curr In
7
Cin Low
18
Enc High
8
Cin In
19
Enc Low
9
Load High
20
Enc In
10
Load Low
For detailed information about setting up Threshold parameters, see
741 Thres 1 High
Default: 100.00%
Range: -300.00% to 300.00%
Level 2
This parameter sets the High Thres level for Threshold 1. For detailed information about setting up Threshold
parameters, see
742 Thres 1 Low
Default: 0.00%
Range: -300.00% to 300.00%
Level 2
This parameter sets the Low Thres level for Threshold 1. For detailed information about setting up Threshold
parameters, see
Table 7-2: Description of X5 Parameters
(Page 26 of 40)
AltRamp2
AltRamp
Ramp Chosen
0
0
Accel Time1 / Decel Time 1
0
1
Accel Time2 / Decel Time 2
1
0
Accel Time3 / Decel Time 3
1
1
Accel Time4 / Decel Time 4