X5 Sequencer Speed Selection
Table 7-5 gives more information on the speed selection options available in the X5 sequencer by
programming bits 0, 1, 2, and 3 of each state’s control parameter. The options include any Preset
Speed, Max Frequency, or allowing the reference to be determined in the normal X5 control path.
X5 Sequencer Ramping Selection
When the sequencer is active, the active ramp is no longer determined by parameter “Ramp Select.”
The user, however, does have the choice of using the main ramps (Accel Time 1/Decel Time1), or
the alternate ramp sets (Accel Time 2/Decel Time 2...3, 4) for each independent state. This is
determined by bits 4 and 5 of the step’s control parameter. The following chart shows the selection
of ramp times based on how bits 4 and 5 are set for the control parameter:
Table 7-5: Speed Selection Options
Binary Value
(refers to bits 0-3)
Definition (Resultant Speed)
0000
Speed selection as in normal X5 operation, as defined by parameters
204
(Ref Select) and
201
(Input Mode).
0001
Value of parameter Preset Freq 1 (
303
)
0010
Value of parameter Preset Freq 2 (
304
)
0011
Value of parameter Preset Freq 3 (
305
)
0100
Value of parameter Preset Freq 4 (
306
)
0101
Value of parameter Preset Freq 5 (
307
)
0110
Value of parameter Preset Freq 6 (
308
)
0111
Value of parameter Preset Freq 7 (
310
)
1000
Value of parameter Preset Freq 8 (
311
)
1001
Value of parameter Preset Freq 9 (
312
)
1010
Value of parameter Preset Freq 10 (
313
)
1011
Value of parameter Preset Freq 11 (
314
)
1100
Value of parameter Preset Freq 12 (
315
)
1101
Value of parameter Preset Freq 13 (
316
)
1110
Value of parameter Preset Freq 14 (
317
)
1111
Value of parameter Preset Freq 15 (
318
)
Table 7-6: Ramp Selection Options
Binary Value
(refers to bits 4-5)
Definition (Resultant Speed)
00
Accel Time 1 and Decel Time 1 will be the ramp times for this step.
01
Accel Time 2 and Decel Time 2 will be the ramp times for this step.
10
Accel Time 3 and Decel Time 3 will be the ramp times for this step.
11
Accel Time 4 and Decel Time 4 will be the ramp times for this step.