X5 AC Drive User’s Manual
Chapter 7: X5 Parameters
DPD00089A
-
72 -
© 2009 Vacon Incorporated All Rights Reserved
031 Pwr Down Time
Read-Only
Range: n/a
Level: 2
The day and time of the last power-down or reset of the drive, in Dd/mm/yy format (example: Tu/09/01).
102 Output Freq
Read-Only
Range: 0.0 to 400.0 Hz
Levels 1,2
Parameter
102
, the
Output Frequency
parameter, shows the frequency being applied to the motor connected to the
drive (ramp).
103 Output Voltage
Read-Only
Range: 0 to 600 V
Levels 1,2
Parameter
103
, the
Output Voltage
parameter, displays the output voltage of the drive.
104 Output Current
Read-Only
Range: 0.0 to 200.0 A
Levels 1,2
Parameter
104
, the
Output Current
parameter, displays the output current of the drive.
105 Drive Load
Read-Only
Range: -200.0% to 200.0%
Levels 1,2
Parameter
105
, the
Drive Load
parameter, shows the percentage torque of the drive when operating below the knee
frequency. It displays Load Torque if the frequency is below FKNEE, and displays Power if above FKNEE.
The output current is measured with the motor power factor applied to an accuracy of ±20%.. The parameter value is
positive when the motor is pulling a load (“motoring mode”) and negative when being pulled by a load (“regenerative
mode”).
106 Load Torque
Read-Only
Range: -200.0%-200.0%
Levels 1,2
Parameter
106
, the
Load Torque
parameter, displays the load torque of the drive.
107 Drive Temp
Read-Only
Range: -20.0 to 200.0 °C
Levels 1,2
Parameter
107
, the
Drive Temp
parameter, shows the actual temperature of the drive’s heatsink. The drive will fault
when the internal temperature reaches 85
°C.
108 Total Run Time
Read-Only
Range: 0.0 - 6553.5 h
Level: 2
Parameter
108
,
Total Run Time
, is a resettable timer for drive operation. To reset the timer, enter 10 in parameter
801,
Program Number
.
109 Power On Hours
Read-only
Range: 0 - 65535 h
Level: 2
Parameter
109
,
Power On Hours
, displays how long the drive has been powered up.
110 Stator Freq
Read-only
Range: 0.0-400.0 Hz
Level: 2
Parameter
110
,
Stator Frequency
, displays the frequency the drive is applying to the motor stator.
111 DC Bus Voltage
Read-only
Range: 0-1000 Vdc
Level: 1,2
Parameter
111
,
DC Bus Voltage
, displays the voltage on the DC bus.
115 Drive Power Out
Read-only
Range: 0.0%-200.0%
Level: 2
This parameter displays the power being output by the drive in terms of drive rating. The measurement is calculated by
scaling the Load Torque value by the ratio of Volt-Amps to Rated Volt-Amps, and adjusted by Output Frequency.
116 Out Power (kW)
Read-only
Range: 0.0 - 327.67 kW
Level: 2
This parameter displays the average instantaneous power being output by the drive, in kW.
Table 7-2: Description of X5 Parameters
(Page 2 of 40)