X5 AC Drive User’s Manual
Chapter 4: Connections
DPD00089A
-
37 -
© 2009 Vacon Incorporated All Rights Reserved
40100
7.5
120
68%
75
8,112
109%
40150
11
120
45%
47
12,944
116%
40200
15
120
34%
47
12,944
87%
40250
18
120
27%
47
12,944
69%
40300
22
120
23%
39
15,600
70%
40400
29.8
60
34%
20
30,420
102%
40500
37.3
60
27%
20
30,420
82%
40600
45
60
23%
15
40,560
91%
40750
55
60
18%
10
60,840
109%
41000
75
60
14%
10
60,840
82%
41250
90
60
11%
10
60,840
65%
41500
110
60
9%
10
60,840
54%
42000
132
60
7%
10
60,840
41%
50010
.75
120
1058%
110
8,607
1154%
50020
1.5
120
529%
110
8,607
577%
50030
2.2
120
353%
110
8,607
385%
50050
3.7
120
212%
110
8,607
231%
50075
5.5
120
141%
91
10,404
186%
50100
7.5
120
106%
91
10,404
139%
50150
11
120
71%
62
15,269
136%
50200
15
120
53%
62
15,269
102%
50250
18
120
42%
62
15,269
82%
50300
22
120
35%
62
15,269
68%
50400
29.8
60
53%
24
39,447
132%
50500
37.3
60
42%
24
39,447
106%
50600
45
60
35%
15
63,115
141%
50750
55
60
28%
15
63,115
113%
51000
75
60
21%
20
63,115
85%
51250
90
60
17%
10
94,672
102%
51500
110
60
14%
10
94,672
85%
52000
132
60
11%
10
94,672
63%
Table 4-7: X5 Dynamic Braking Capacity
(Page 2 of 2)
(* Note that the asterisked X5 model numbers cannot
have external braking added)
Model
KW
Standard
Resistance
(ohms)
Standard DB
(% of Drive
Power)
Min. Allowed
Res. (ohms)
Max. Peak
Watts
Max. Ext. DB
(% of Drive
Power)