Goodrive10 inverters Function codes
53
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P08.08
Jogging
running DEC
time
inverter goes from the Max. Frequency (P0.03) to 0Hz.
Setting range:0.0~3600.0s
Depend
on model
○
P08.15
Traverse
range
This function applies to the industries where traverse and
convolution function are required such as textile and
chemical fiber.
The traverse function means that the output frequency of
the inverter is fluctuated with the set frequency as its
center. The route of the running frequency is illustrated as
below, of which the traverse is set by P08.15 and when
P08.15 is set as 0, the traverse is 0 with no function.
Traverse range: The traverse running is limited by upper
and low frequency.
The traverse range relative to the center frequency:
traverse range AW
=
center frequency×traverse range
P08.15.
Sudden jumping frequency
=
traverse range AW×sudden
jumping frequency range P08.16. When run at the traverse
frequency, the value which is relative to the sudden jumping
frequency.
The raising time of the traverse frequency: The time from
the lowest point to the highest one.
The declining time of the traverse frequency: The time from
the highest point to the lowest one.
The setting range of P08.15: 0.0~100.0%(relative to the set
frequency)
The setting range of P08.16: 0.0~50.0%(relative to the
traverse range)
The setting range of P08.17: 0.1~3600.0s
The setting range of P08.18: 0.1~3600.0s
0.0%
○
P08.16
Sudden
jumping
frequency
range
0.0%
○
P08.17
Traverse boost
time
5.0s
○
P08.18
Traverse
declining time
5.0s
○