Goodrive10 inverters Keypad operation procedure
23
4.1.2 Displayed state of running parameters
After the inverter receives valid running commands, the inverter will enter into the running state and the
keypad will display the running parameters. RUN/TUNE LED on the keypad is on, while the FWD/REV is
determined by the current running direction which is shown as figure 4-2.
In the running state, there are 22 parameters can be selected to be displayed or not. They are: running
frequency, set frequency, bus voltage, output voltage, output torque, PID reference, PID feedback, input
terminals state, output terminals state, and the current stage of multi-stage speeds, pulse counting value, AI1,
AI2, percentage of motor overload, percentage of inverter overload, linear speed. P07.05 and P07.06 can
select the parameter to be displayed or not by bit and
》
/SHIFT can shift the parameters form left to right,
QUICK/JOG (P07.02=2) can shift the parameters from right to left.
4.1.3 Displayed state of fault
If the inverter detects the fault signal, it will enter into the fault pre-alarm displaying state. The keypad will
display the fault code by flicking. The TRIP LED on the keypad is on, and the fault reset can be operated by
the STOP/RST on the keypad, control terminals or communication commands.
4.1.4 Displayed state of function codes editing
In the state of stopping, running or fault, press PRG/ESC to enter into the editing state (if there is a password,
see P07.00 ).The editing state is displayed on two classes of menu, and the order is: function code
group/function code number→function code parameter, press
DATA/ENT into the displayed state of function
parameter. On this state, press DATA/ENT to save the parameters or press PRG/ESC to escape.
Fig 4-2 Displayed state