g3Xflash
Expander Flash Utility
Version: 14.1.0.0
Copyright 2016 Avago Technologies.
All rights reserved.
********************************************************************************
Initializing Interface.
Expander: SledgeHammer_3 (SAS_35X_36)
Expander reset request successfully sent to expander.
Note:
Please add -w parameter for non-disruptive firmware update to avoid SAS I/O interrupt.
User may need to execute above commands at the same time to avoid runtime version
compatibility/inconsist- ent issue or Linux driver noisy messages.
Checking Expander Version Using Linux
To check the expander firmware version using Linux:
1.
Log into the Linux terminal.
2.
Open the Terminal.
3.
Create a temporary folder
/expander
.
4.
Copy g3Xflash utility to
/expander
folder.
5.
Execute the following command to scan expander devices and obtain four
Expander SAS addresses:
./g3Xflash -i get avail
.
[root@expander]# ./g3Xflash -i get avail
********************************************************************************
g3Xflash
Expander Flash Utility
Version: 14.1.0.0
Copyright 2016 Avago Technologies.
All rights reserved.
********************************************************************************
Initializing Interface.
Expander: SledgeHammer_2 (SAS_35X_36)
1)
SledgeHammer_2 (SAS_35X_36) (51C666DF:B6CB203F)
2)
SledgeHammer_0 (SAS_35X_36) (51C666DF:B6CB803F)
3)
SledgeHammer_1 (SAS_35X_36) (51C666DF:B6CB903F)
4)
SledgeHammer_3 (SAS_35X_36) (51C666DF:B6CB303F)
Summary of Contents for SSR-4N108L
Page 1: ...JBOD SSR 4N108L User Manual ...
Page 16: ...System Architecture ...
Page 61: ...Signal Cable Routing ...