System Operations
This section provides information about getting your JBOD up and running
Powering on
Follow these steps to turn on the system:
1.
Connect the power cord to the power socket at the rear of the JBOD and plug
the other end into a power outlet.
2.
Press the power button once to turn on the JBOD.
Powering down
Follow these steps to power down the system:
1.
Press and hold the power button to turn off the JBOD.
2.
Disconnect the power cord from the power socket.
Set Storage Configuration
Prior to shipping, the system configuration is setup according to customer
requirements. The system does not require further configuration prior to powering
on.
Set steps with BMC IPMI command
Before starting this procedure, make sure the JBOD is powered on.
1.
Log into Linux.
2.
Open the terminal.
3.
Execute the ipmitool command to select specified Topology mode on all installed
expanders (1~4).
Command:
#ipmitool –H <ip address> -U <username> -P <password> -I lanplus raw 0x30 0x04
<Expander ID> 0xa0 <Mode Selection>
Hint:
<Expander ID>: ID of specified expander, must be 1 ~ 4.
<Mode Selection>: 0x01: Standard / 0x02: Warm / 0x03: Cold / 0x04: Shared
Note:
All installed expanders must be assigned the same mode.