User Guide
796
RMON Configurations
Switch(config)#rmon alarm
1
stats-index
1
alarm-variable
bpkt
s-type
absolute
rising-
threshold
3000
rising-event-index
1
falling-threshold
2000
falling-event-index
2
a-type
all
interval
10
owner
monitor
Switch(config)#show rmon alarm
Index-State: 1-Enabled
Statistics index: 1
Alarm variable: BPkt
Sample Type: Absolute
RHold-REvent: 3000-1
FHold-FEvent: 2000-2
Alarm startup: All
Interval: 10
Owner: monitor
Switch(config)#end
Switch#copy running-config startup-config