User Guide
679
Configuring IPv6 IMPB
ND Detection Configuration
Step 3
ipv6 nd detection vlan
vlan-range
Enable ND Detection on the specified VLAN.
vlan-range:
Enter the vlan range in the format of 1-3, 5.
Step 4
ipv6 nd detection vlan
vlan-range
logging
(Optional) Enable the Log feature to make the switch generate a log when an ND packet is
discarded.
vlan-range:
Enter the vlan range in the format of 1-3, 5.
Step 5
show ipv6 nd detection
Verify the global ND Detection configuration.
Step 6
end
Return to privileged EXEC mode.
Step 7
copy running-config startup-config
Save the settings in the configuration file.
The following example shows how to enable ND Detection globally and on VLAN 1:
Switch#configure
Switch(config)#ipv6 nd detection
Switch(config)#ipv6 nd detection vlan
1
Switch(config)#show ipv6 nd detection
Global Status: Enable
Switch(config)#show ipv6 nd detection vlan
VID Enable status Log Status
---- ------------- ----------
1 Enable Disable
Switch(config)#end
Switch#copy running-config startup-config
3.2.3 Configuring ND Detection on Ports
Follow these steps to configure ND Detection on ports:
Step 1
configure
Enter global configuration mode.
Downloaded from