E6581442
11
K-38
[30] My function [5/5]
Sensorless vector/vector with sensor (
●
:Effective, -:Ineffective)
Vector control
Title
Communi
cation
No.
Function Adjustment
range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Speed
control
Torque
control
PM
control V/f Constant Reference
0962
Analog input function target 21
0:Disabled
1:VI/II
2:RR/S4
3:RX
4:Optional AI1+, Optional AI1-
5:Optional AI2
6:Internal memory2
1/1 0
Enabled
●
/
●
●
/
●
●
●
*1
0964
Analog function assigned object
21
0~10 1/1
0
Disabled
●
/
●
●
/
●
●
●
*1
0965
Monitor output function target 11 2000~2099:FD00~FD99
3000~3099:FE00~FE99
1/1 2000
Enabled
●
/
●
●
/
●
●
●
*1
0966
Monitor output function
command 11
0:Normal monitor, 1:Max. value, 2:Min. value
1/1
0
Enabled
●
/
●
●
/
●
●
●
*1
0967
Monitor output function target
21
2000~2099:FD00~FD99
3000~3099:FE00~FE99
1/1 2000
Enabled
●
/
●
●
/
●
●
●
*1
0968
Monitor output function
command 21
0:Normal monitor, 1:Max. value, 2:Min. value
1/1
0
Enabled
●
/
●
●
/
●
●
●
*1
0969
Monitor output function target
31
2000~2099:FD00~FD99
3000~3099:FE00~FE99
1/1 2000
Enabled
●
/
●
●
/
●
●
●
*1
0970
Monitor output function
command 31
0:Normal monitor, 1:Max. value, 2:Min. value
1/1
0
Enabled
●
/
●
●
/
●
●
●
*1
0971
Monitor output function target
41
2000~2099:FD00~FD99
3000~3099:FE00~FE99
1/1 2000
Enabled
●
/
●
●
/
●
●
●
*1
0972
Monitor output function
command 41
0:Normal monitor, 1:Max. value, 2:Min. value
1/1
0
Enabled
●
/
●
●
/
●
●
●
*1
0973
Virtual input terminal selection 1 0~135 *2
1/1
0
Disabled
●
/
●
●
/
●
●
●
*1
0974
Virtual input terminal selection 2 0~135 *2
1/1
0
Disabled
●
/
●
●
/
●
●
●
*1
0975
Virtual input terminal selection 3 0~135 *2
1/1
0
Disabled
●
/
●
●
/
●
●
●
*1
0976
Virtual input terminal selection 4 0~135 *2
1/1
0
Disabled
●
/
●
●
/
●
●
●
*1
0977 My
function
selection
0:Disabled
1:My fu permission signal
2:My function always ON
1/1 0
Disabled
●
/
●
●
/
●
●
●
*1
*1:
For details, refer to Instruction Manual (E6581335) specified in Section 6.42. *2:
For the adjustment range, see the table on page K-43.
[31] Travenirse function
Sensorless vector/vector with sensor (
●
:Effective, -:Ineffective)
Vector control
Title
Communi
cation
No.
Function Adjustment
range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Speed
control
Torque
control
PM
control V/f Constant Reference
0980 Traverse
selection
0:Disabled
1:Enabled
1/1 0
Disabled
●
/
●
-
●
●
*1
0981
Traverse acceleration time
0.1~120.0 sec.
0.1/0.1
25.0
Enabled
●
/
●
-
●
●
*1
0982
Traverse deceleration time
0.1~120.0 sec.
0.1/0.1
25.0
Enabled
●
/
●
-
●
●
*1
0983 Traverse
step
0.0~25.0%
0.1/0.1 10.0 Enabled
●
/
●
-
●
●
*1
0984
Traverse jump step
0.0~50.0%
0.1/0.1
10.0
Enabled
●
/
●
-
●
●
*1
*1:
For details, refer to Instruction Manual (E6581337) specified in Section 6.42.