E6581442
E-5
5
5.4
Setting parameters by operating method
: Automatic function setting
[Parameter setting]
Title
Function
Adjustment range
Default setting
Automatic function
setting
:Disabled
:Frequency setting by means of voltage
:Frequency setting by means of current
:Voltage/current switching from external terminal
:Frequency setting on operation panel and operation by means of terminal
:Frequency setting and operation on operation panel
Example:
When setting the parameter "
=
", It will be the following indication.
Automatically programmed functions and parameter set values
Default
setting
:
Disabled
:
Frequency setting
by means of
voltage
:
Frequency setting
by means of
current
:
Voltage/current
switching from
external terminal
:
Frequency setting
on operation panel
and operation by
means of terminal
:
Frequency setting
and operation on
operation panel
:Terminal
board
–
– – –
:Terminal board
:Operation panel
:RR/S4 –
:RR/S4
:VI/II
:RR/S4
:Operation
panel
:Operation
panel
:Voltage
input
– –
:Current input
:Current input
–
–
(S3)
:Preset
speed
command 3
– –
–
:Frequency
priority switching
– –
:
/
terminal
switching
–
:
/
terminal
switching
:
/
terminal
switching
:
/
terminal
switching
:
/
terminal
switching
:
/
terminal
switching
%
–
–
%
%
–
–
:VI/II –
:RR/S4
:VI/II
:VI/II
:Operation
panel
:Operation
panel
Refer to Section 11 for input terminal functions.
No change is made to the parameter setting.
Operation is performed by applying a voltage for setting the RR/S4 terminal 1 frequency.
When sink logic is selected:
PWR-P24/PLC ON:
Standby (ON (short-circuited) by default)
F-CC ON: Forward run
R-CC ON: Reverse run
This setting is used to set the frequency by applying a current of 4-20mA to the VI/II terminal.
PWR-P24/PLC ON:
Standby (ON (short-circuited) by default)
F-CC ON:
Forward run
R-CC ON:
Reverse run
Switching between remote and local (different frequency commands) can be performed by turning on or off the S3 terminal.
In that case, apply a voltage via the RR/S4 terminal and a current via the VI/II terminal.
S3-CC OFF: The frequency is set according to the voltage applied to the RR/S4 terminal.
S3-CC ON: The frequency is set according to the current applied to the VI/II terminal.
In sink logic mode: PWR-P24/PLC ON: Standby (ON (short-circuited) by default), F-CC ON: Forward run, R-CC ON:
Reverse run.
• Function
Automatically programs all parameters (parameters described below) related to the functions by
selecting the inverter's operating method.
The major functions can be programmed simply.
Disabled (
=
)
Frequency setting by means of voltage: (
=
)
Frequency setting by means of current (
=
)
Voltage/current switching by means of an external terminal (
=
)
ENT
3 times
A present set value is shown.
ENT
ENT