K-13
E6581442
11
[14] Functions for lift [1/2]
Sensorless vector/vector with sensor (
●
:Effective, -:Ineffective)
Vector control
Title
Communi
cation
No.
Function Adjustment
range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Speed
control
Torque
control
PM
control
V/f Reference
0324
Drooping output filter
0.1~200.0 rad/s (Enabled if
=3, 4, 7 or 8)
0.1/0.1
100.0
Enabled
●
/
●
- - - 6.
15
0328
Light-load high-speed operation
selection
0:Disabled
1:High-speed operation speed set automatically
(Power running at F command: Increase)
2:High-speed operation speed set automatically
(Power running at R command: Increase)
3:High-speed operation speed set with
(Power running at F command: Increase)
4:High-speed operation speed set with
(Power running at R command: Increase)
1/1 0
Disabled
●
/
●
-
●
●
*1
0329
Light-load high-speed learning function 0:No learning, 1:Forward run learning
2:Reverse run learning
1/1 0
Disabled
●
/
●
- - - *1
0330
Automatic light-load high-speed
operation frequency
30.0~
Hz
0.1/0.01
*2
Enabled
●
/
●
-
●
●
*1
0331
Light-load high-speed operation
switching lower limit frequency
5.0~
Hz
0.1/0.01
40.0
Enabled
●
/
●
-
●
●
*1
0332
Light-load high-speed operation
load waiting time
0.0~10.0 sec.
0.1/0.1
0.5
Enabled
●
/
●
-
●
●
*1
0333
Light-load high-speed operation
load detection time
0.0~10.0 sec.
0.1/0.1
1.0
Enabled
●
/
●
-
●
●
*1
0334
Light-load high-speed operation
heavy load detection time
0.0~10.0 sec.
0.1/0.1
0.5
Enabled
●
/
●
-
●
●
*1
0335
Switching load torque during
power running
-250~250% 1/0.01
50
Enabled
●
/
●
-
●
●
*1
0336
Heavy-load torque during power running -250~250% 1/0.01
100
Enabled
●
/
●
-
●
●
*1
0337
Heavy-load torque during
constant power running
-250~250% 1/0.01
50
Enabled
●
/
●
-
●
●
*1
0338
Switching load torque during
regenerative braking
-250~250% 1/0.01
50
Enabled
●
/
●
-
●
●
*1
0340
Creeping time 1
0.00~2.50 sec.
0.01/0.01
0
Enabled
●
/
●
- - - 6.
17
0341 Braking
mode
selection
0:Disabled, 1:Forward winding up
2:Reverse winding up, 3:Horizontal operation
1/1 0
Disabled
●
/
●
- - - 6.
17
0342
Load portion torque input
selection
0:Disabled, 1:VI/II (voltage/current input)
2:RR/S4 (potentiometer/voltage input)
3:RX (voltage input)
4:
enabled
5:2-wire RS485 communication input
6:4-wire RS485 communication input
7:Communications option input enabled
8:Optional AI1 (differential current input)
1/1 4
Enabled
●
/
●
- - - 6.
17
0343
Hoisting torque bias input (valid
only when
=
)
-250~250% 1/0.01
100
Enabled
●
/
●
- - - 6.
17
0344
Lowering torque bias multiplier 0~100%
1/0.01
100
Enabled
●
/
●
- - - 6.
17
0345
Brake release time
0.00~2.50 sec.
0.01/0.01
0.05
Enabled
●
/
●
- - - 6.
17
0346 Creeping
frequency
~20.0 Hz
0.1/0.01
3.0
Disabled
●
/
●
- - - 6.
17
0347
Creeping time 2
0.00~2.50 sec.
0.01/0.01
0.10
Enabled
●
/
●
- - - 6.
17
*1: