K-35
E6581442
11
[30] My function [2/5]
Sensorless vector/vector with sensor (
●
:Effective, -:Ineffective)
Vector control
Title
Communi
cation
No.
Function Adjustment
range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Speed
control
Torque
control
PM
control V/f Constant Reference
0901
Input function command 12
0:NOP (not operation)
1:ST (move)
2:STN
3:AND (logical product)
4:ANDN
5:OR (logical sum)
6:ORN
7:EQ (equal)
8:NE (not equal)
9:GT (greater than)
10:GE (greater or equal)
11:LT (less than)
12:LE (less or equal)
13:ASUB (absolute)
14:ON (on delay timer)
15:OFF (off delay timer)
16:COUNT 1 (counter 1)
17:COUNTR 2 (counter 2)
18:HOLD (hold)
19:SET (set)
20:RESET (reset)
21:CLR
22:CLRN
1/1 0
Disabled
●
/
●
●
/
●
●
●
*1
0902
Input function target 12
Same as
1/1
0
Disabled
●
/
●
●
/
●
●
●
*1
0903
Input function command 13
Same as
1/1
0
Disabled
●
/
●
●
/
●
●
●
*1
0904
Input function target 13
Same as
1/1
0
Disabled
●
/
●
●
/
●
●
●
*1
0905
Output function assigned object
1
Same as
1/1
0
Disabled
●
/
●
●
/
●
●
●
*1
0906
Input function target 21
Same as
1/1
0
Disabled
●
/
●
●
/
●
●
●
*1
0907
Input function command 22
Same as
1/1
0
Disabled
●
/
●
●
/
●
●
●
*1
0908
Input function target 22
Same as
1/1
0
Disabled
●
/
●
●
/
●
●
●
*1
0909
Input function command 23
Same as
1/1
0
Disabled
●
/
●
●
/
●
●
●
*1
0910
Input function target 23
Same as
1/1
0
Disabled
●
/
●
●
/
●
●
●
*1
0911
Output function assigned object
2
Same as
1/1
0
Disabled
●
/
●
●
/
●
●
●
*1
0912
Input function target 31
Same as
1/1
0
Disabled
●
/
●
●
/
●
●
●
*1
0913
Input function command 32
Same as
1/1
0
Disabled
●
/
●
●
/
●
●
●
*1
0914
Input function target 32
Same as
1/1
0
Disabled
●
/
●
●
/
●
●
●
*1
*1:
For details, refer to Instruction Manual (E6581335) specified in Section 6.42.