E6581442
11
K-14
[14] Functions for lift [2/2]
Sensorless vector/vector with sensor (
●
:Effective, -:Ineffective)
Vector control
Title
Communi
cation
No.
Function Adjustment
range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Speed
control
Torque
control
PM
control
V/f Reference
0348
Braking time learning function
0:Disabled
1:Brake signal learning (0 after adjustment)
1/1 0
Enabled
●
/
●
- - - 6.
17
0349
Acceleration/deceleration
suspend function
0:Disabled, 1:Parameter setting, 2:Terminal input
1/1
0
Disabled
●
/
●
-
●
●
6.
18
0350
Acceleration suspend frequency 0.0~
Hz
0.1/0.01
0.0
Enabled
●
/
●
-
●
●
6.
18
0351
Acceleration suspend time
0.0~10.0 sec.
0.1/0.1
0.0
Enabled
●
/
●
-
●
●
6.
18
0352 Deceleration
suspend
frequency 0.0~
Hz
0.1/0.01
0.0
Enabled
●
/
●
-
●
●
6.
18
0353
Deceleration suspend time
0.0~10.0 sec.
0.1/0.1
0.0
Enabled
●
/
●
-
●
●
6.
18
[15] Commercial/inverter switching function
Sensorless vector/vector with sensor (
●
:Effective, -:Ineffective)
Vector control
Title
Communi
cation
No.
Function Adjustment
range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Speed
control
Torque
control
PM
control
V/f Reference
0354
Commercial power/inverter
switching output selection
0:Disabled
1:Automatic switching in the event of a trip
2:Commercial power switching frequency setting
3:Commercial power switching frequency s
automatic switching in the event of a trip
1/1 0
Disabled
●
/
●
●
/
●
●
●
6.
19
0355
Commercial power/inverter
switching frequency
0~
Hz
0.1/0.01
*2
Enabled
●
/
●
●
/
●
●
●
6.
19
0356
Inverter-side switching waiting
time
0.10~10.00 sec.
0.01/0.01
*1
Enabled
●
/
●
●
/
●
●
●
6.
19
0357
Commercial power-side
switching waiting time
0.40~10.00 sec.
0.01/0.01
0.62
Enabled
●
/
●
●
/
●
●
●
6.
19
0358
Commercial power switching
frequency holding time
0.10~10.00 sec.
0.01/0.01
2.00
Enabled
●
/
●
●
/
●
●
●
6.
19
*1: Default values vary depending on the capacity.
See the table of K-48. *2: Inverter with a model number ending with -WN1: 60.0 -WP1: 50.0
[16] PID control [1/2] Sensorless vector/vector with sensor (
●
:Effective, -:Ineffective)
Vector control
Title
Communi
cation
No.
Function Adjustment
range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Speed
control
Torque
control
PM
control
V/f Reference
0359 PID
control
switching
0:No PID control
1:Process type PID control (temp./pressure, etc.)
operation
2:Speed type PID control (potentiometer, etc.)
operation
3:Stop retaining P control
4.Dancer control
1/1 0
Disabled
●
/
●
-
●
●
*1,
*2
*1:
For details, refer to Instruction Manual (E6581319) specified in Section 6.42. *2:
For details, refer to Instruction Manual (E6581329) specified in Section 6.42.