TMP92CF30
2009-06-12
92CF30-523
AD Conversion Result Register 2 Low
7 6 5 4 3 2 1 0
bit
Symbol
ADR21
ADR20
OVR2
ADR2RF
Read/Write R
R
Reset
State
0
0 0
0
ADREG2L
(12A4H)
Function
Store Lower 2 bits of
AN2 AD conversion
result
Overrun
flag
0:No
generate
1: Generate
AD
conversion
result store
flag
1: Stored
AD Conversion Result Register 1 High
7 6 5 4 3 2 1 0
bit Symbol
ADR29
ADR28
ADR27
ADR26 ADR25 ADR24 ADR23 ADR22
Read/Write R
Reset
State
0 0 0 0 0 0 0 0
ADREG2H
(12A5H)
Function
Store Upper 8 bits of AN2 AD conversion result
AD Conversion Result Register 3 Low
7 6 5 4 3 2 1 0
bit
Symbol
ADR31
ADR30
OVR3
ADR3RF
Read/Write R
R
Reset
State
0
0 0
0
ADREG3L
(12A6H)
Function
Store Lower 2 bits of
AN3 AD conversion
result
Overrun
flag
0:No
generate
1: Generate
AD
conversion
result store
flag
1: Stored
AD Conversion Result Register 3 High
7 6 5 4 3 2 1 0
bit Symbol
ADR39
ADR38
ADR37
ADR36 ADR35 ADR34 ADR33 ADR32
Read/Write R
Reset
State
0 0 0 0 0 0 0 0
ADREG3H
(12A7H)
Function
Store Upper 8 bits of AN3 AD conversion result
9
8
7
6
5
4
3
2
1
0
Channel X conversion
result
7 6
5
4
3
2
1
0
7
6
5
4 3 2 1 0
Figure 3.22.7 AD Conversion Registers
•
Bits 5
∼
2 are always read as “0”.
•
Bit 0 is the AD conversion result store flag <ADRxRF>. When AD conversion result is stored, the flag is set to
“1”. When Lower register (ADRECxL) is read, this bit is cleared to “0”.
•
Bit 1 is the Overrun flag <OVRx>. This bit is set to “1” if a next conversion result is written to the
ADREGxH/L before both the ADREGxH and ADREGxL are read. This bit is cleared to “0” by reading Flag.
ADREGxH ADREGxL
Summary of Contents for TLCS-900/H1 Series
Page 652: ...TMP92CF30 2009 06 12 92CF30 650 ...