TMP92CF30
2009-06-12
92CF30-421
(c) Issuance of NULL packet
If transmitting NULL packet, by input L pulse from EPx_EOPB signal, data of
0 length is set to FIFO, and NULL packet can be transferred to IN token.
But if NULL data is set to FIFO, it is valid only in the case whole SET signal is
L level condition (where FIFO is empty). If it answer to receiving IN token by
using NULL packet in a certain period, it is answered by keeping EPx_EOPB
signal to L level.
However, if mode is dual packet mode, EPx_DATASET signal assert L level for
showing space of data. Therefore, data condition (whether either has data or not)
cannot be confirmed externally.
Note: NULL packet can also be set by accessing EOP register.
Example:
(2) Interrupt control
Interrupt signal is prepared. This function use adept system.
For detail refer to 3.16.2 900/H1 CPU I/F.
DATASET_A
DATASET_B
EPx_EOPB
NULL
A
Neglect
NULL
B
NULL
A
NULL
B
NULL
A
NULL packet
completion of
transmitting
Summary of Contents for TLCS-900/H1 Series
Page 652: ...TMP92CF30 2009 06 12 92CF30 650 ...