TMP92CF30
2009-06-12
92CF30-478
Note: When Monaural is set, Right data and Left data output the same-signal. When Stereo is set, the data of FIFO
buffer is renewed every one-word. However, when Monaural is set, it is renewed to the next data after the
same-data is transmitted two times.
When Monaural is set, it output the same-data to Right and Left, without the same-data written to the FIFO
buffer.
The Monaural function of TMP92CZ26A/CF26A and TMP92CF30 is different.
The Monaural function of TMP92CZ26A/CF26A is one of channels only.
Figure3.18.3 Output Format
LSB MSB
LSB
MSB
LSB
MSB
I2S0WS
LSB
MSB
LSB
MSB
LSB
Valid data
Valid Data
Valid Data
Valid Data
MSB
LSB
MSB
LSB
MSB
Left justify
I2S0DO
Stereo
Valid Data
Valid Data
Right Data
Left Data
Right justify
I2S0DO
Stereo
I
2
S format
I2S0DO
Stereo
I2S0CKO
LSB
MSB
LSB
Valid Data
Monaural
LSB
MSB
LSB
MSB
Valid Data
Monaural
MSB
LSB
MSB
Monaural
Valid Data
Summary of Contents for TLCS-900/H1 Series