TMP92CF30
2009-06-12
92CF30-311
Protocol
1.
Select 9-Bit UART Mode on the master and slave controllers.
2.
Set the SC0MOD0<WU> bit on each slave controller to “1” to enable data receiving.
3.
The master controller transmits data one frame at a time. Each frame includes an 8-bit
select code which identifies a slave controller. The MSB (bit 8) of the data (<TB8>) is
set to “1”.
4.
Each slave controller receives the above frame. Each controller checks the above select
code against its own select code. The controller whose code matches clears its <WU>
bit to “0”.
5.
The master controller transmits data to the specified slave controller (the controller
whose SC0MOD0<WU> bit has been cleared to “0”). The MSB (bit 8) of the data
(<TB8>) is cleared to “0”.
6.
The other slave controllers (whose <WU> bits remain at 1) ignore the received data
because their MSBs (bit 8 or <RB8>) are set to “0”, disabling INTRX0 interrupts.
The slave controller whose <WU> bit = “0” can also transmit to the master controller.
In this way it can signal the master controller that the data transmission from the
master controller has been completed.
Start Bit0 1
2
3
4
5
6
Select code of slave controller
7
Stop
8
“1”
Data
“0”
Start
Bit0 1 2
3
4
5
6
7
Stop
Bit8