Outdoor unit
:
RAS
‐
2M18S3AV
‐
E , -A , -TR
<
Cooling / 220V >
Unit capacity
Total
(kW)
Cooling capacity
Power consumption
Operating current
A
B
C
Σ
kBTU
A
B
C
(kW)
(W)
(A)
1 unit
07
-
-
7
2.00
-
-
2.0
400
2.32
(
1.3
-
3.0
) (
240
-
840 ) (
1.42
-
4.09
)
10
-
-
10
2.70
-
-
2.7
640
3.39
(
1.3
-
3.2
) (
240
-
860 ) (
1.42
-
4.18
)
13
-
-
13
3.70
-
-
3.7
1050
5.08
(
1.4
-
4.2
) (
240
-
1400 ) (
1.42
-
6.71
)
16
-
-
16
4.50
-
-
4.5
1330
6.39
(
1.5
-
5.0
) (
250
-
1680 ) (
1.48
-
8.01
)
2 units
07
07
-
14
2.00
2.00
-
4.0
940
4.56
(
1.7
-
5.5
) (
270
-
1700 ) (
1.60
-
8.10
)
10
07
-
17
2.70
2.00
-
4.7
1260
6.06
(
1.7
-
5.8
) (
270
-
1830 ) (
1.60
-
8.70
)
13
07
-
20
3.38
1.82
-
5.2
1490
7.13
(
1.7
-
5.9
) (
270
-
1840 ) (
1.60
-
8.75
)
16
07
-
23
3.60
1.60
-
5.2
1390
6.66
(
1.7
-
6.2
) (
270
-
1870 ) (
1.60
-
8.89
)
10
10
-
20
2.60
2.60
-
5.2
1520
7.27
(
1.7
-
5.9
) (
270
-
1840 ) (
1.60
-
8.75
)
13
10
-
23
3.01
2.19
-
5.2
1480
7.08
(
1.7
-
6.0
) (
270
-
1850 ) (
1.60
-
8.79
)
16
10
-
26
3.25
1.95
-
5.2
1370
6.57
(
1.7
-
6.3
) (
270
-
1870 ) (
1.60
-
8.89
)
13
13
-
26
2.60
2.60
-
5.2
1430
6.85
(
1.7
-
6.1
) (
270
-
1850 ) (
1.60
-
8.79
)
16
13
-
29
2.85
2.35
-
5.2
1340
6.43
(
1.7
-
6.2
) (
270
-
1880 ) (
1.60
-
8.93
)
16
16
-
32
2.60
2.60
-
5.2
1300
6.25
(
1.7
-
6.4
) (
270
-
1900 ) (
1.60
-
9.02
)
・
The above specification values are those under the conditions that the indoor DB/WB=27/19
℃
and the outdoor DB/WB=35/–
℃
.
<
Cooling / 230V >
Unit capacity
Total
(kW)
Cooling capacity
Power consumption
Operating current
A
B
C
Σ
kBTU
A
B
C
(kW)
(W)
(A)
1 unit
07
-
-
7
2.00
-
-
2.0
400
2.22
(
1.3
-
3.0
) (
240
-
840 ) (
1.36
-
3.91
)
10
-
-
10
2.70
-
-
2.7
640
3.24
(
1.3
-
3.2
) (
240
-
860 ) (
1.36
-
4.00
)
13
-
-
13
3.70
-
-
3.7
1050
4.86
(
1.4
-
4.2
) (
240
-
1400 ) (
1.36
-
6.42
)
16
-
-
16
4.50
-
-
4.5
1330
6.11
(
1.5
-
5.0
) (
250
-
1680 ) (
1.42
-
7.66
)
2 units
07
07
-
14
2.00
2.00
-
4.0
940
4.36
(
1.7
-
5.5
) (
270
-
1700 ) (
1.53
-
7.75
)
10
07
-
17
2.70
2.00
-
4.7
1260
5.80
(
1.7
-
5.8
) (
270
-
1830 ) (
1.53
-
8.32
)
13
07
-
20
3.38
1.82
-
5.2
1490
6.82
(
1.7
-
5.9
) (
270
-
1840 ) (
1.53
-
8.37
)
16
07
-
23
3.60
1.60
-
5.2
1390
6.37
(
1.7
-
6.2
) (
270
-
1870 ) (
1.53
-
8.50
)
10
10
-
20
2.60
2.60
-
5.2
1520
6.95
(
1.7
-
5.9
) (
270
-
1840 ) (
1.53
-
8.37
)
13
10
-
23
3.01
2.19
-
5.2
1480
6.77
(
1.7
-
6.0
) (
270
-
1850 ) (
1.53
-
8.41
)
16
10
-
26
3.25
1.95
-
5.2
1370
6.29
(
1.7
-
6.3
) (
270
-
1870 ) (
1.53
-
8.50
)
13
13
-
26
2.60
2.60
-
5.2
1430
6.55
(
1.7
-
6.1
) (
270
-
1850 ) (
1.53
-
8.41
)
16
13
-
29
2.85
2.35
-
5.2
1340
6.15
(
1.7
-
6.2
) (
270
-
1880 ) (
1.53
-
8.54
)
16
16
-
32
2.60
2.60
-
5.2
1300
5.97
(
1.7
-
6.4
) (
270
-
1900 ) (
1.53
-
8.63
)
・
The above specification values are those under the conditions that the indoor DB/WB=27/19
℃
and the outdoor DB/WB=35/–
℃
.
Operating
status
Indoor unit
Operating
status
Indoor unit
FILE NO. SVM-15102
- 15 -